* Copyright (c) 2012-2022 DSR Corporation, Denver CO, USA
|
|
* Copyright (c) 2021-2022 Espressif Systems (Shanghai) PTE LTD
|
|
* All rights reserved.
|
|
*
|
|
*
|
|
* Redistribution and use in source and binary forms, with or without modification,
|
|
* are permitted provided that the following conditions are met:
|
|
*
|
|
* 1. Redistributions of source code must retain the above copyright notice,
|
|
* this list of conditions and the following disclaimer.
|
|
*
|
|
* 2. Redistributions in binary form, except as embedded into a Espressif Systems
|
|
* integrated circuit in a product or a software update for such product,
|
|
* must reproduce the above copyright notice, this list of conditions and
|
|
* the following disclaimer in the documentation and/or other materials
|
|
* provided with the distribution.
|
|
*
|
|
* 3. Neither the name of the copyright holder nor the names of its contributors
|
|
* may be used to endorse or promote products derived from this software without
|
|
* specific prior written permission.
|
|
*
|
|
* 4. Any software provided in binary form under this license must not be reverse
|
|
* engineered, decompiled, modified and/or disassembled.
|
|
*
|
|
* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
|
|
* AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
|
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
|
* ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE
|
|
* LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
|
|
* CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
|
|
* SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
|
|
* INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
|
|
* CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
|
|
* ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
|
|
* POSSIBILITY OF SUCH DAMAGE.
|
|
*/
|
|
/* PURPOSE: Metering cluster definitions
|
|
*/
|
|
|
|
#ifndef ZB_ZCL_METERING_H
|
|
#define ZB_ZCL_METERING_H 1
|
|
|
|
#include "zcl/zb_zcl_common.h"
|
|
#include "zcl/zb_zcl_commands.h"
|
|
|
|
|
|
/** @cond DOXYGEN_ZCL_SECTION */
|
|
|
|
/** @addtogroup ZB_ZCL_METERING
|
|
* @{
|
|
* @details
|
|
* The Metering Cluster provides a mechanism to retrieve usage information
|
|
* from Electric, Gas, Water, and potentially Thermal metering devices.
|
|
*/
|
|
|
|
/** @defgroup ZB_ZCL_METERING_CLI_ATTRS Metering cluster client attributes and enumerations
|
|
* @{
|
|
*/
|
|
|
|
/** @brief Metering cluster client attribute sets
|
|
* @see SE 1.4 spec, table D.58.
|
|
*/
|
|
enum zb_zcl_metering_cli_attr_set_e
|
|
{
|
|
ZB_ZCL_METERING_SET_CLI_NOTIFICATION_ATTRIBUTE = 0x00, /**< Notification Attribute Set */
|
|
};
|
|
|
|
|
|
/** @brief Metering cluster client attributes */
|
|
enum zb_zcl_metering_cli_attr_e
|
|
{
|
|
ZB_ZCL_ATTR_METERING_CLI_FUNCTIONAL_NOTIFICATION_FLAGS = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_CLI_NOTIFICATION_ATTRIBUTE, 0x00),
|
|
/**< @e FunctionalNotificationFlags attribute is implemented as a set of bit flags
|
|
* which are have a predefined action associated with a bit that is not based on a specific command,
|
|
* but may require the Mirrored device to trigger some additional functionality within the system */
|
|
ZB_ZCL_ATTR_METERING_CLI_NOTIFICATION_FLAGS2, /**< @e NotificationFlagsN are 32-bit bitmaps that each represent a series of flags.
|
|
* Each flag represents an outstanding command that the Mirror is holding on behalf of the BOMD.
|
|
* Each flag represents a different command.
|
|
* The format of these attributes is dictated by the scheme that is currently in operation. */
|
|
ZB_ZCL_ATTR_METERING_CLI_NOTIFICATION_FLAGS3, /**< @copydoc ZB_ZCL_ATTR_METERING_CLI_NOTIFICATION_FLAGS2 */
|
|
ZB_ZCL_ATTR_METERING_CLI_NOTIFICATION_FLAGS4, /**< @copydoc ZB_ZCL_ATTR_METERING_CLI_NOTIFICATION_FLAGS2 */
|
|
ZB_ZCL_ATTR_METERING_CLI_NOTIFICATION_FLAGS5, /**< @copydoc ZB_ZCL_ATTR_METERING_CLI_NOTIFICATION_FLAGS2 */
|
|
ZB_ZCL_ATTR_METERING_CLI_NOTIFICATION_FLAGS6, /**< @copydoc ZB_ZCL_ATTR_METERING_CLI_NOTIFICATION_FLAGS2 */
|
|
ZB_ZCL_ATTR_METERING_CLI_NOTIFICATION_FLAGS7, /**< @copydoc ZB_ZCL_ATTR_METERING_CLI_NOTIFICATION_FLAGS2 */
|
|
ZB_ZCL_ATTR_METERING_CLI_NOTIFICATION_FLAGS8, /**< @copydoc ZB_ZCL_ATTR_METERING_CLI_NOTIFICATION_FLAGS2 */
|
|
};
|
|
|
|
/** @} */ /* ZB_ZCL_METERING_CLI_ATTRS */
|
|
|
|
/** @defgroup ZB_ZCL_METERING_SRV_ATTRS Metering cluster server attributes and enumerations
|
|
* @{
|
|
*/
|
|
|
|
/** @brief Metering cluster server attribute sets
|
|
* @see SE 1.4 spec, table D.10.
|
|
*/
|
|
enum zb_zcl_metering_srv_attr_set_e
|
|
{
|
|
ZB_ZCL_METERING_SET_READ_INFO = 0x00, /**< Reading Information Set */
|
|
ZB_ZCL_METERING_SET_TOU_INFORMATION = 0x01, /**< TOU Information Set */
|
|
ZB_ZCL_METERING_SET_METER_STATUS = 0x02, /**< Meter Status */
|
|
ZB_ZCL_METERING_SET_FORMATTING = 0x03, /**< Formatting */
|
|
ZB_ZCL_METERING_SET_HISTORICAL_CONSUMPTION = 0x04, /**< Historical Consumption */
|
|
ZB_ZCL_METERING_SET_LOAD_PROFILE_CONFIGURATION = 0x05, /**< Load Profile Configuration */
|
|
ZB_ZCL_METERING_SET_SUPPLY_LIMIT = 0x06, /**< Supply Limit */
|
|
ZB_ZCL_METERING_SET_BLOCK_INFORMATION_DELIVERED = 0x07, /**< Block Information (Delivered) */
|
|
ZB_ZCL_METERING_SET_ALARMS = 0x08, /**< Alarms */
|
|
ZB_ZCL_METERING_SET_BLOCK_INFORMATION_RECEIVED = 0x09, /**< Block Information (Received) */
|
|
ZB_ZCL_METERING_SET_METER_BILLING = 0x0A, /**< Meter Billing Attribute Set */
|
|
ZB_ZCL_METERING_SET_SUPPLY_CONTROL = 0x0B, /**< Supply Control Attribute Set */
|
|
ZB_ZCL_METERING_SET_ALTERNATIVE_HISTORICAL_CONSUMPTION = 0x0C, /**< Alternative Historical Consumption */
|
|
ZB_ZCL_METERING_SET_FOUR_QUADRANT_ELECTRICITY = 0x0D, /**< Four-Quadrant Electricity */
|
|
};
|
|
|
|
|
|
/** @brief Metering cluster server attributes */
|
|
enum zb_zcl_metering_attr_e
|
|
{
|
|
/* Reading Information Attribute Set, table D.11 */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_SUMMATION_DELIVERED_ID = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_READ_INFO, 0x00), /**< @e CurrentSummationDelivered attribute
|
|
* represents the most recent summed value of Energy, Gas, or Water delivered and consumed
|
|
* in the premises. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_SUMMATION_RECEIVED_ID, /**< @e CurrentSummationReceived attribute represents the most recent summed value of Energy,
|
|
* Gas, or Water generated and delivered from the premises. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_MAX_DEMAND_DELIVERED_ID, /**< @e CurrentMaxDemandDelivered attribute represents the maximum demand or rate of delivered
|
|
* value of Energy, Gas, or Water being utilized at the premises. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_MAX_DEMAND_RECEIVED_ID, /**< @e CurrentMaxDemandReceived attribute represents the maximum demand or rate of received
|
|
* value of Energy, Gas, or Water being utilized by the utility. */
|
|
ZB_ZCL_ATTR_METERING_DFT_SUMMATION_ID, /**< @e DFTSummation attribute represents a snapshot of attribute CurrentSummationDelivered
|
|
* captured at the time indicated by attribute @ref ZB_ZCL_ATTR_METERING_DAILY_FREEZE_TIME_ID "DailyFreezeTime". */
|
|
ZB_ZCL_ATTR_METERING_DAILY_FREEZE_TIME_ID, /**< @e DailyFreezeTime attribute represents the time of day when DFTSummation is captured
|
|
* (hour and minutes). */
|
|
ZB_ZCL_ATTR_METERING_POWER_FACTOR_ID, /**< @e PowerFactor attribute contains the Average Power Factor ratio in 1/100th. Valid
|
|
* values are 0 to 99. */
|
|
ZB_ZCL_ATTR_METERING_READING_SNAPSHOT_TIME_ID, /**< @e ReadingSnapshotTime attribute represents the last time all of the
|
|
* @ref ZB_ZCL_ATTR_METERING_CURRENT_SUMMATION_DELIVERED_ID "CurrentSummationDelivered",
|
|
* @ref ZB_ZCL_ATTR_METERING_CURRENT_SUMMATION_RECEIVED_ID "CurrentSummationReceived",
|
|
* @ref ZB_ZCL_ATTR_METERING_CURRENT_MAX_DEMAND_DELIVERED_ID "CurrentMaxDemandDelivered" and
|
|
* @ref ZB_ZCL_ATTR_METERING_CURRENT_MAX_DEMAND_RECEIVED_ID "CurrentMaxDemandReceived"
|
|
* attributes that are supported by the device were updated. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_MAX_DEMAND_DELIVERED_TIME_ID, /**< @e CurrentMaxDemandDeliveredTime attribute represents the represents the time when
|
|
* @ref ZB_ZCL_ATTR_METERING_CURRENT_MAX_DEMAND_DELIVERED_ID "CurrentMaxDemandDelivered" reading
|
|
* was captured. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_MAX_DEMAND_RECEIVED_TIME_ID, /**< @e CurrentMaxDemandReceivedTime attribute represents the time when
|
|
* @ref ZB_ZCL_ATTR_METERING_CURRENT_MAX_DEMAND_RECEIVED_ID "CurrentMaxDemandReceived reading
|
|
* was captured. */
|
|
ZB_ZCL_ATTR_METERING_DEFAULT_UPDATE_PERIOD_ID, /**< @e DefaultUpdatePeriod attribute represents the interval (seconds) at which the
|
|
* @ref ZB_ZCL_ATTR_METERING_INSTANTANEOUS_DEMAND_ID "InstantaneousDemand" attribute is
|
|
* updated when not in fast poll mode. */
|
|
ZB_ZCL_ATTR_METERING_FAST_POLL_UPDATE_PERIOD_ID, /**< @e FastPollUpdatePeriod attribute represents the interval (seconds) at which the
|
|
* @ref ZB_ZCL_ATTR_METERING_INSTANTANEOUS_DEMAND_ID "InstantaneousDemand" attribute is
|
|
* updated when in fast poll mode. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_BLOCK_PERIOD_CONSUMPTION_DELIVERED_ID, /**< @e CurrentBlockPeriodConsumptionDelivered attribute represents the most recent summed
|
|
* value of Energy, Gas or Water delivered and consumed in the premises during the Block
|
|
* Tariff Period. */
|
|
ZB_ZCL_ATTR_METERING_DAILY_CONSUMPTION_TARGET_ID, /**< @e DailyConsumptionTarget attribute is a daily target consumption amount that can be
|
|
* displayed to the consumer on a HAN device, with the intent that it can be used to compare
|
|
* to actual daily consumption. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_BLOCK_ID, /**< @e CurrentBlock attribute is an 8-bit Enumeration which indicates the currently active
|
|
* block, when Block Tariffs are enabled. @see zb_zcl_metering_block_e */
|
|
ZB_ZCL_ATTR_METERING_PROFILE_INTERVAL_PERIOD_ID, /**< @e ProfileIntervalPeriod attribute is currently included in the @e GetProfileResponse
|
|
* command payload, but does not appear in an attribute set. It represents the interval or
|
|
* time frame used to capture metered Energy, Gas, and Water consumption for profiling purposes. */
|
|
/* 0x0010 attribute is deprecated */
|
|
ZB_ZCL_ATTR_METERING_PRESET_READING_TIME_ID = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_READ_INFO, 0x11), /**< @e PresetReadingTime attribute */
|
|
ZB_ZCL_ATTR_METERING_SUMMATION_DELIVERED_PER_REPORT_ID, /**< @e SummationDeliveredPerReport attribute represents the summation increment per report
|
|
* from the water or gas meter. */
|
|
ZB_ZCL_ATTR_METERING_FLOW_RESTRICTION_ID, /**< @e FlowRestriction attribute represents the volume per minute limit set in the flow
|
|
* restrictor. This applies to water but not for gas. A setting of 0xFF indicates this
|
|
* feature is disabled. */
|
|
ZB_ZCL_ATTR_METERING_SUPPLY_STATUS_ID, /**< @e SupplyStatus attribute represents the state of the supply at the customer's premises.
|
|
* @see zb_zcl_metering_supply_status_e */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_INLET_ENERGY_CARRIER_SUMMATION_ID, /**< @e CurrentInletEnergyCarrierSummation attribute is the current integrated volume of a
|
|
* given energy carrier measured on the inlet. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_OUTLET_ENERGY_CARRIER_SUMMATION_ID, /**< @e CurrentOutletEnergyCarrierSummation attribute is the current integrated volume of a
|
|
* given energy carrier measured on the outlet. */
|
|
ZB_ZCL_ATTR_METERING_INLET_TEMPERATURE_ID, /**< @e InletTemperature attribute is the temperature measured on the energy carrier inlet. */
|
|
ZB_ZCL_ATTR_METERING_OUTLET_TEMPERATURE_ID, /**< @e OutletTemperature attribute is the temperature measured on the energy carrier outlet. */
|
|
ZB_ZCL_ATTR_METERING_CONTROL_TEMPERATURE_ID, /**< @e ControlTemperature attribute is a reference temperature measured on the meter used to
|
|
* validate the Inlet/Outlet temperatures. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_INLET_ENERGY_CARRIER_DEMAND_ID, /**< @e CurrentInletEnergyCarrierDemand attribute is the current absolute demand on the energy
|
|
* carrier inlet. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_OUTLET_ENERGY_CARRIER_DEMAND_ID, /**< @e CurrentOutletEnergyCarrierDemand attribute is the current absolute demand on the energy
|
|
* carrier outlet. */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_BLOCK_PERIOD_CONSUMPTION_DELIVERED_ID, /**< @e PreviousBlockPeriodConsumptionDelivered attribute represents the total value of Energy,
|
|
* Gas or Water delivered and consumed in the premises at the end of the previous Block Tariff
|
|
* period. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_BLOCK_PERIOD_CONSUMPTION_RECEIVED_ID, /**< @e CurrentBlockPeriodConsumptionReceived attribute represents the most recent summed
|
|
* value of Energy, Gas or Water received by the energy supplier from the premises during
|
|
* the Block Tariff Period. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_BLOCK_RECEIVED_ID, /**< @e CurrentBlockReceived attribute is an 8-bit Enumeration which indicates the currently
|
|
* active block, when Block Tariffs are enabled. */
|
|
ZB_ZCL_ATTR_METERING_DFT_SUMMATION_RECEIVED_ID, /**< @e DFTSummationReceived attribute represents a snapshot of attribute
|
|
* @ref ZB_ZCL_ATTR_METERING_CURRENT_SUMMATION_RECEIVED_ID "CurrentSummationReceived"
|
|
* captured at the time indicated by the
|
|
* @ref ZB_ZCL_ATTR_METERING_DAILY_FREEZE_TIME_ID "DailyFreezeTime" attribute. */
|
|
ZB_ZCL_ATTR_METERING_ACTIVE_REGISTER_TIER_DELIVERED_ID, /**< @e ActiveRegisterTierDelivered attribute indicates the current register tier that the
|
|
* energy consumed is being accumulated against. @see SE 1.4 spec, table D.98. */
|
|
ZB_ZCL_ATTR_METERING_ACTIVE_REGISTER_TIER_RECEIVED_ID, /**< @e ActiveRegisterTierReceived attribute indicates the current register tier that the
|
|
* energy generated is being accumulated against. @see SE 1.4 spec, table D.101. */
|
|
ZB_ZCL_ATTR_METERING_LAST_BLOCK_SWITCH_TIME_ID, /**< @e LastBlockSwitchTime attribute allows other devices to determine the time at which
|
|
* a meter switches from one block to another. */
|
|
ZB_ZCL_ATTR_METERING_NUMBER_OF_TIERS_IN_USE, /**< @e NumberofTiersInUse */
|
|
|
|
/* 0x0024 to 0x00FF reserved */
|
|
|
|
|
|
/* TOU Information Attribute Set, table D.14 */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_TOU_INFORMATION, 0x00), /**< @e CurrentTierNSummationDelivered
|
|
* attributes represent the most recent summed value of Energy, Gas, or Water delivered to the premises at a
|
|
* specific price tier as defined by a TOU schedule or a real time pricing period. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID, /**< @e CurrentTierNSummationReceived attributes represent the most recent summed value of Energy, Gas, or Water
|
|
* provided by the premises (i.e. received by the utility from the customer) at a specific price tier as defined
|
|
* by a TOU schedule or a real time pricing period. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER2_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER2_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER3_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER3_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER4_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER4_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER5_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER5_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER6_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER6_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER7_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER7_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER8_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER8_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER9_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER9_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER10_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER10_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER11_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER11_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER12_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER12_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER13_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER13_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER14_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER14_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER15_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER15_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER16_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER16_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER17_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER17_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER18_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER18_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER19_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER19_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER20_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER20_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER21_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER21_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER22_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER22_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER23_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER23_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER24_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER24_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER25_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER25_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER26_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER26_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER27_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER27_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER28_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER28_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER29_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER29_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER30_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER30_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER31_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER31_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER32_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER32_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER33_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER33_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER34_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER34_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER35_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER35_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER36_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER36_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER37_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER37_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER38_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER38_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER39_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER39_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER40_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER40_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER41_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER41_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER42_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER42_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER43_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER43_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER44_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER44_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER45_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER45_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER46_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER46_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER47_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER47_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER48_SUMMATION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_TIER48_SUMMATION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_CURRENT_TIER1_SUMMATION_RECEIVED_ID */
|
|
/* 0x0160 to 0x01FB reserved */
|
|
ZB_ZCL_ATTR_METERING_CPP1_SUMMATION_DELIVERED_ID = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_TOU_INFORMATION, 0xFC), /**< @e CPP1SummationDelivered attribute
|
|
* represents the most recent summed value of Energy, Gas, or Water delivered to the premises (i.e.
|
|
* delivered to the customer from the utility) while Critical Peak Price CPP1 was being applied. */
|
|
/* 0x01FD reserved */
|
|
ZB_ZCL_ATTR_METERING_CPP2_SUMMATION_DELIVERED_ID = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_TOU_INFORMATION, 0xFE), /**< @e CPP2SummationDelivered attribute
|
|
* represents the most recent summed value of Energy, Gas, or Water delivered to the premises (i.e.
|
|
* delivered to the customer from the utility) while Critical Peak Price CPP2 was being applied. */
|
|
/* 0x01FF reserved */
|
|
|
|
|
|
/* Meter Status Attribute Set, table D.15. */
|
|
ZB_ZCL_ATTR_METERING_STATUS_ID = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_METER_STATUS, 0x00), /**< @e Status attribute provides indicators reflecting the current
|
|
* error conditions found by the metering device. Status depends on the device type.
|
|
* @see zb_zcl_metering_status_electricity_e
|
|
* @see zb_zcl_metering_status_gas_e
|
|
* @see zb_zcl_metering_status_water_e
|
|
* @see zb_zcl_metering_status_heat_cooling_e */
|
|
ZB_ZCL_ATTR_METERING_REMAINING_BATTERY_LIFE_ID, /**< @e RemainingBatteryLife attribute represents the estimated remaining life of the battery in % of capacity.
|
|
* A setting of 0xFF indicates this feature is disabled. */
|
|
ZB_ZCL_ATTR_METERING_HOURS_IN_OPERATION_ID, /**< @e HoursInOperation attribute is a counter that increments once every hour during operation. */
|
|
ZB_ZCL_ATTR_METERING_HOURS_IN_FAULT_ID, /**< @e HoursInFault attribute is a counter that increments once every hour when the device is in operation
|
|
* with a fault detected. */
|
|
ZB_ZCL_ATTR_METERING_EXTENDED_STATUS_ID, /**< @e ExtendedStatus attribute reflects the state of items in a meter that the standard Status attribute
|
|
* cannot show. The Extended Status BitMap is split into two groups of flags: general flags and metering
|
|
* type specific flags.
|
|
* @see zb_zcl_metering_extstatus_general_e
|
|
* @see zb_zcl_metering_extstatus_electricity_e
|
|
* @see zb_zcl_metering_extstatus_gas_e */
|
|
ZB_ZCL_ATTR_METERING_REMAINING_BATTERY_LIFE_DAYS_ID, /**< @e RemainingBatteryLifeInDays attribute represents the estimated remaining life of the battery in days
|
|
* of capacity. The range is 0 - 0xFFFE, where 0xFFFF represents 'Invalid', 'Unused' and 'Disabled'. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_METER_ID_ID, /**< @e CurrentMeterID attribute is the current id for the Meter. This could be the current firmware
|
|
* version supported on the meter. */
|
|
ZB_ZCL_ATTR_METERING_AMBIENT_CONSUMPTION_INDICATOR_ID, /**< @e AmbientConsumptionIndicator attribute is an 8-bit enumeration which provides a simple indication
|
|
* (Low/Medium/High) of the amount of a commodity being consumed within the premises.
|
|
* @see @ref zb_zcl_metering_low_medium_high_status_e. */
|
|
ZB_ZCL_ATTR_METERING_SERVICE_DISCONNECT_REASON_ID, /**< The Service Disconnect Reason attribute is an 8-bit enumeration which indicates why the supply
|
|
* to the premises has been disconnected */
|
|
ZB_ZCL_ATTR_METERING_LINKY_MODE_OF_OPERATION_ID, /**< The @e LinkyModeOfOperation attribute is specific to Linky devices. It consists of a single flag
|
|
* (bit 0) which shall be set to FALSE (0) when in 'Simple' Mode and set to TRUE (1) when in
|
|
* Advanced Mode. Bits 1 to 7 are reserved. */
|
|
/* 0x020A to 0x02FF reserved */
|
|
|
|
|
|
/* Formatting Attribute Set, table D.25 */
|
|
ZB_ZCL_ATTR_METERING_UNIT_OF_MEASURE_ID = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_FORMATTING, 0x00), /**< @e UnitOfMeasure attribute provides a label for
|
|
* the Energy, Gas, or Water being measured by the metering device.
|
|
* @see zb_zcl_metering_unit_of_measure_e */
|
|
ZB_ZCL_ATTR_METERING_MULTIPLIER_ID, /**< @e Multiplier attribute provides a value to be multiplied against a raw or uncompensated sensor
|
|
* count of Energy, Gas, or Water being measured by the metering device. */
|
|
ZB_ZCL_ATTR_METERING_DIVISOR_ID, /**< @e Divisor attribute provides a value to divide the results of applying the
|
|
* @ref ZB_ZCL_ATTR_METERING_MULTIPLIER_ID "Multiplier Attribute" against a raw or uncompensated
|
|
* sensor count of Energy, Gas, or Water being measured by the metering device. */
|
|
ZB_ZCL_ATTR_METERING_SUMMATION_FORMATTING_ID, /**< @e SummationFormatting attribute provides a method to properly decipher the number of digits
|
|
* and the decimal location of the values found in the Summation Information Set of attributes. */
|
|
ZB_ZCL_ATTR_METERING_DEMAND_FORMATTING_ID, /**< @e DemandFormatting attribute provides a method to properly decipher the number of digits and
|
|
* the decimal location of the values found in the Demand-related attributes. */
|
|
ZB_ZCL_ATTR_METERING_HISTORICAL_CONSUMPTION_FORMATTING_ID, /**< @e HistoricalConsumptionFormatting attribute provides a method to properly decipher the number
|
|
* of digits and the decimal location of the values found in the Historical Consumption Set of
|
|
* attributes. */
|
|
ZB_ZCL_ATTR_METERING_METERING_DEVICE_TYPE_ID, /**< @e MeteringDeviceType attribute provides a label for identifying the type of metering device
|
|
* present (Energy, Gas, Water, Thermal, Heat, Cooling, and mirrored metering devices).
|
|
* @see zb_zcl_metering_device_type_e */
|
|
ZB_ZCL_ATTR_METERING_SITE_ID_ID, /**< @e SiteID attribute is a text string, known in the UK as the MPAN number for electricity,
|
|
* MPRN for gas and 'Stand Point' in South Africa. */
|
|
ZB_ZCL_ATTR_METERING_METER_SERIAL_NUMBER_ID, /**< @e MeterSerialNumber attribute is used to provide a unique identification of the metering
|
|
* device. */
|
|
ZB_ZCL_ATTR_METERING_ENERGY_CARRIER_UNIT_OF_MEASURE_ID, /**< @e EnergyCarrierUnitOfMeasure attribute specifies the unit of measure that the EnergyCarrier
|
|
* is measured in. */
|
|
ZB_ZCL_ATTR_METERING_ENERGY_CARRIER_SUMMATION_FORMATTING_ID, /**< @e EnergyCarrierSummationFormatting attribute provides a method to properly decipher the number
|
|
* of digits and the decimal location of the values found in the Summation- related attributes. */
|
|
ZB_ZCL_ATTR_METERING_ENERGY_CARRIER_DEMAND_FORMATTING_ID, /**< @e EnergyCarrierDemandFormatting attribute provides a method to properly decipher the number
|
|
* of digits and the decimal location of the values found in the Demand- related attributes. */
|
|
ZB_ZCL_ATTR_METERING_TEMPERATURE_UNIT_OF_MEASURE_ID, /**< @e TemperatureUnitOfMeasure attribute specifies the unit of measure that temperatures are
|
|
* measured in.
|
|
* @see zb_zcl_metering_temperature_unit_of_measure_e */
|
|
ZB_ZCL_ATTR_METERING_TEMPERATURE_FORMATTING_ID, /**< @e TemperatureFormatting attribute provides a method to properly decipher the number of digits
|
|
* and the decimal location of the values found in the Temperature-related attributes. */
|
|
ZB_ZCL_ATTR_METERING_MODULE_SERIAL_NUMBER_ID, /**< @e ModuleSerialNumber attribute represents the serial number (unique identifier) of the
|
|
* meter module. */
|
|
ZB_ZCL_ATTR_METERING_OPERATING_TARIFF_LABEL_DELIVERED_ID, /**< @e OperatingTariffLabelDelivered attribute is the meter's version of the @e TariffLabel attribute
|
|
* that is found within the Tariff Information attribute set of the Price Cluster. */
|
|
ZB_ZCL_ATTR_METERING_OPERATING_TARIFF_LABEL_RECEIVED_ID, /**< @e OperatingTariffLabelReceived attribute is the meter's version of the @e ReceivedTariffLabel
|
|
* attribute that is found within the Tariff Information attribute set of the Price Cluster. */
|
|
ZB_ZCL_ATTR_METERING_CUSTOMER_ID_NUMBER_ID, /**< @e CustomerIDNumber attribute provides a customer identification which may be used to confirm
|
|
* the customer at the premises. */
|
|
ZB_ZCL_ATTR_METERING_ALTERNATIVE_UNIT_OF_MEASURE_ID, /**< @e AlternativeUnitOfMeasure attribute provides a base for the attributes in the Alternative
|
|
* Historical Consumption attribute set. */
|
|
ZB_ZCL_ATTR_METERING_ALTERNATIVE_DEMAND_FORMATTING_ID, /**< @e AlternativeDemandFormatting attribute provides a method to properly decipher the number of
|
|
* digits and the decimal location of the values found in the Alternative Demand-related attributes. */
|
|
ZB_ZCL_ATTR_METERING_ALTERNATIVE_CONSUMPTION_FORMATTING_ID, /**< @e AlternativeConsumptionFormatting attribute provides a method to properly decipher the
|
|
* number of digits and the decimal location of the consumption values found in the Alternative
|
|
* Historical Consumption Set of attributes. */
|
|
/* 0x0313 to 0x03FF reserved */
|
|
|
|
|
|
/* Historical Consumption Attribute Set, table D.29 */
|
|
ZB_ZCL_ATTR_METERING_INSTANTANEOUS_DEMAND_ID = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_HISTORICAL_CONSUMPTION, 0x00), /**< @e InstantaneousDemand attribute
|
|
* represents the current Demand of Energy, Gas, or Water delivered or received at the premises.*/
|
|
ZB_ZCL_ATTR_METERING_CURRENT_DAY_CONSUMPTION_DELIVERED_ID, /**< @e CurrentDayConsumptionDelivered attribute represents the summed value of Energy,
|
|
* Gas, or Water delivered to the premises since the Historical Freeze Time (HFT).*/
|
|
ZB_ZCL_ATTR_METERING_CURRENT_DAY_CONSUMPTION_RECEIVED_ID, /**< @e CurrentDayConsumptionReceived attribute represents the summed value of Energy,
|
|
* Gas, or Water received from the premises since the Historical Freeze Time (HFT). */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY_CONSUMPTION_DELIVERED_ID, /**< @e PreviousDayConsumptionDelivered attribute represents the summed value of Energy,
|
|
* Gas, or Water delivered to the premises within the previous 24 hour period starting
|
|
* at the Historical Freeze Time (HFT). */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY_CONSUMPTION_RECEIVED_ID, /**< @e PreviousDayConsumptionReceived attribute represents the summed value of Energy,
|
|
* Gas, or Water received from the premises within the previous 24 hour period starting
|
|
* at the Historical Freeze Time (HFT). */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_PARTIAL_PROFILE_INTERVAL_START_TIME_DELIVERED_ID, /**< @e CurrentPartialProfileIntervalStartTimeDelivered attribute represents the start
|
|
* time of the current Load Profile interval being accumulated for commodity delivered. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_PARTIAL_PROFILE_INTERVAL_START_TIME_RECEIVED_ID, /**< @e CurrentPartialProfileIntervalStartTimeReceived attribute represents the start
|
|
* time of the current Load Profile interval being accumulated for commodity received. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_PARTIAL_PROFILE_INTERVAL_VALUE_DELIVERED_ID, /**< @e CurrentPartialProfileIntervalValueDelivered attribute represents the value of
|
|
* the current Load Profile interval being accumulated for commodity delivered. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_PARTIAL_PROFILE_INTERVAL_VALUE_RECEIVED_ID, /**< @e CurrentPartialProfileIntervalValueReceived attribute represents the value of
|
|
* the current Load Profile interval being accumulated for commodity delivered. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_DAY_MAX_PRESSURE_ID, /**< @e CurrentDayMaxPressure attribute is the maximum pressure reported during a day
|
|
* from the water or gas meter. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_DAY_MIN_PRESSURE_ID, /**< @e CurrentDayMinPressure attribute is the minimum pressure reported during a day
|
|
* from the water or gas meter. */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY_MAX_PRESSURE_ID, /**< @e PreviousDayMaxPressure attribute is the maximum pressure reported during previous
|
|
* day from the water or gas meter. */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY_MIN_PRESSURE_ID, /**< @e PreviousDayMinPressure attribute is the minimum pressure reported during previous
|
|
* day from the water or gas meter. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_DAY_MAX_DEMAND_ID, /**< @e CurrentDayMaxDemand attribute represents the maximum demand or rate of delivered
|
|
* value of Energy, Gas, or Water being utilized at the premises. */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY_MAX_DEMAND_ID, /**< @e PreviousDayMaxDemand attribute represents the maximum demand or rate of delivered
|
|
* value of Energy, Gas, or Water being utilized at the premises. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_MONTH_MAX_DEMAND_ID, /**< @e CurrentMonthMaxDemand attribute is the maximum demand reported during a month
|
|
* from the meter. For electricity, heat and cooling meters this is the maximum power
|
|
* reported in a month.*/
|
|
ZB_ZCL_ATTR_METERING_CURRENT_YEAR_MAX_DEMAND_ID, /**< @e CurrentYearMaxDemand attribute is the maximum demand reported during a year
|
|
* from the meter. For electricity, heat and cooling meters this is the maximum power
|
|
* reported in a year.*/
|
|
ZB_ZCL_ATTR_METERING_CURRENT_DAY_MAX_ENERGY_CARRIER_DEMAND_ID, /**< @e CurrentDayMaxEnergyCarrierDemand attribute is the maximum energy carrier demand
|
|
* reported during a day from the meter. For heat and cooling meters this is the maximum
|
|
* flow rate on the inlet reported in a day.
|
|
* @note At the end of a day the meter will transfer the @e CurrentDayMaxEnergyCarrierDemand
|
|
* into @ref ZB_ZCL_ATTR_METERING_PREVIOUS_DAY_MAX_ENERGY_CARRIER_DEMAND_ID "PreviousDayMaxEnergyCarrierDemand". */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY_MAX_ENERGY_CARRIER_DEMAND_ID, /**< @e PreviousDayMaxEnergyCarrierDemand attribute is the maximum energy carrier demand
|
|
* reported during the previous day from the meter. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_MONTH_MAX_ENERGY_CARRIER_DEMAND_ID, /**< @e CurrentMonthMaxEnergyCarrierDemand attribute is the maximum energy carrier demand
|
|
* reported during a month from the meter. For heat and cooling meters this is the
|
|
* maximum flow rate on the inlet reported in a month. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_MONTH_MIN_ENERGY_CARRIER_DEMAND_ID, /**< @e CurrentMonthMinEnergyCarrierDemand attribute is the minimum energy carrier demand
|
|
* reported during a month from the meter. For heat and cooling meters this is the
|
|
* minimum flow rate on the inlet reported in a month. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_YEAR_MAX_ENERGY_CARRIER_DEMAND_ID, /**< @e CurrentYearMaxEnergyCarrierDemand attribute is the maximum energy carrier demand
|
|
* reported during a year from the meter. For heat and cooling meters this is the maximum
|
|
* flow rate on the inlet reported in a year. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_YEAR_MIN_ENERGY_CARRIER_DEMAND_ID, /**< @e CurrentYearMinEnergyCarrierDemand attribute is the minimum energy carrier demand
|
|
* reported during a year from the heat meter. For heat and cooling meters this is the
|
|
* minimum flow rate on the inlet reported in a year. */
|
|
/* 0x0417 to 0x041F reserved */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY2_CONSUMPTION_DELIVERED_ID = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_HISTORICAL_CONSUMPTION, 0x20), /**< @e PreviousDayNConsumptionDelivered
|
|
* attribute represents the summed value of Energy, Gas, or Water delivered to the
|
|
* premises within the previous 24 hour period starting at the Historical Freeze Time (HFT). */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY2_CONSUMPTION_RECEIVED_ID, /**< @e PreviousDayNConsumptionReceived attribute represents the summed value of Energy,
|
|
* Gas, or Water received from the premises within the previous 24 hour period starting
|
|
* at the Historical Freeze Time (HFT). */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY3_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_DAY2_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY3_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_DAY2_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY4_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_DAY2_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY4_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_DAY2_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY5_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_DAY2_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY5_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_DAY2_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY6_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_DAY2_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY6_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_DAY2_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY7_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_DAY2_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY7_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_DAY2_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY8_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_DAY2_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY8_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_DAY2_CONSUMPTION_RECEIVED_ID */
|
|
/* 0x042E to 0x042F reserved */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_WEEK_CONSUMPTION_DELIVERED_ID = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_HISTORICAL_CONSUMPTION, 0x30), /**< @e CurrentWeekConsumptionDelivered
|
|
* attribute represents the summed value of Energy, Gas, or Water delivered to the premises
|
|
* since the Historical Freeze Time (HFT) on Monday to the last HFT read. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_WEEK_CONSUMPTION_RECEIVED_ID, /**< @e CurrentWeekConsumptionReceived attribute represents the summed value of Energy,
|
|
* Gas, or Water received from the premises since the Historical Freeze Time (HFT) on
|
|
* Monday to the last HFT read. */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK_CONSUMPTION_DELIVERED_ID, /**< @e PreviousWeekNConsumptionDelivered attribute represents the summed value of Energy,
|
|
* Gas, or Water delivered to the premises within the previous week period starting at
|
|
* the Historical Freeze Time (HFT) on the Monday to the Sunday. */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK_CONSUMPTION_RECEIVED_ID, /**< @e PreviousWeekNConsumptionReceived attribute represents the summed value of Energy,
|
|
* Gas, or Water received from the premises within the previous week period starting at
|
|
* the Historical Freeze Time (HFT) on the Monday to the Sunday. */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK2_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK2_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK3_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK3_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK4_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK4_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK5_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK5_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK_CONSUMPTION_RECEIVED_ID */
|
|
/* 0x043C to 0x043F reserved */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_MONTH_CONSUMPTION_DELIVERED_ID = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_HISTORICAL_CONSUMPTION, 0x40), /**< @e CurrentMonthConsumptionDelivered
|
|
* attribute represents the summed value of Energy, Gas, or Water delivered to the premises
|
|
* since the Historical Freeze Time (HFT) on the 1 st of the month to the last HFT read. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_MONTH_CONSUMPTION_RECEIVED_ID, /**< @e CurrentMonthConsumptionReceived attribute represents the summed value of Energy,
|
|
* Gas, or Water received from the premises since the Historical Freeze Time (HFT) on the
|
|
* 1 st of the month to the last HFT read. */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_DELIVERED_ID, /**< @e PreviousMonthNConsumptionDelivered attribute represents the summed value of
|
|
* Energy, Gas, or Water delivered to the premises within the previous Month period
|
|
* starting at the Historical Freeze Time (HFT) on the 1 st of the month to the last
|
|
* day of the month.*/
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_RECEIVED_ID, /**< @e PreviousMonthNConsumptionReceived attribute represents the summed value of
|
|
* Energy, Gas, or Water received from the premises within the previous month period
|
|
* starting at the Historical Freeze Time (HFT) on the 1 st of the month to the last
|
|
* day of the month.*/
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH2_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH2_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH3_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH3_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH4_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH4_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH5_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH5_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH6_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH6_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH7_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH7_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH8_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH8_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH9_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH9_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH10_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH10_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH11_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH11_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH12_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH12_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH13_CONSUMPTION_DELIVERED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_DELIVERED_ID */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH13_CONSUMPTION_RECEIVED_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_CONSUMPTION_RECEIVED_ID */
|
|
ZB_ZCL_ATTR_METERING_HISTORICAL_FREEZE_TIME_ID, /**< @e HistoricalFreezeTime attribute represents the time of day, in Local Time, when
|
|
* Historical Consumption attributes and/or Alternative Historical Consumption
|
|
* attributes are captured (hour and minutes). */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_DAY_MAX_DEMAND_DELIVERED_ID, /**< @e CurrentDayMaxDemandDelivered represents the maximum demand or rate of delivered value of
|
|
* Energy, Gas, or Water being utilized at the premises since the Historical Freeze Time (HFT). */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_DAY_MAX_DEMAND_DELIVERED_TIME_ID, /**< The @e CurrentDayMaxDemandDeliveredTime attribute represents the time when
|
|
* @e CurrentDayMaxDemandDelivered reading was captured. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_DAY_MAX_DEMAND_RECEIVED_ID, /**< @e CurrentDayMaxDemandReceived represents the maximum demand or rate of received value of
|
|
* Energy, Gas, or Water being utilized by the utility from the premises sinc e the Historical
|
|
* Freeze Time (HFT). */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_DAY_MAX_DEMAND_RECEIVED_TIME_ID, /**< The CurrentDayMaxDemandReceivedTime attribute represents the time CurrentDayMaxDemandReceived
|
|
* reading was captured */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY_MAX_DEMAND_DELIVERED_ID, /**< @e PreviousDayMaxDemandDelivered represents the maximum demand or rate of delivered
|
|
* value of Energy, Gas, or Water that was utilized at the premises within the previous 24
|
|
* hour period starting at the Historical Freeze Time (HFT) */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY_MAX_DEMAND_DELIVERED_TIME_ID, /**< The @e PreviousDayMaxDemandDeliveredTime attribute represents the time when
|
|
* PreviousDayMaxDemandDelivered reading was captured. */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY_MAX_DEMAND_RECEIVED_ID, /**< @e PreviousDayMaxDemandReceived represents the maximum demand or rate of received value
|
|
* of Energy, Gas, or Water that was utilized by the utility from the premises within the
|
|
* previous 24 hour period starting at the Historical Freeze Time (HFT).
|
|
*/
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY_MAX_DEMAND_RECEIVED_TIME_ID, /**< The @e PreviousDayMaxDem andReceivedTime attribute represents the time when
|
|
* @e PreviousDayMaxDemandReceived reading was captured.
|
|
*/
|
|
/* 0x045D to 0x04FF reserved */
|
|
|
|
|
|
/* Load Profile Configuration Attribute Set, table D.30 */
|
|
ZB_ZCL_ATTR_METERING_MAX_NUMBER_OF_PERIODS_DELIVERED_ID = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_LOAD_PROFILE_CONFIGURATION, 0x00), /**< @e MaxNumberOfPeriodsDelivered
|
|
* attribute represents the maximum number of intervals the device is capable of returning
|
|
* in one Get Profile Response command. It is required @e MaxNumberOfPeriodsDelivered fit
|
|
* within the default Fragmentation ASDU size of 128 bytes, or an optionally agreed upon
|
|
* larger Fragmentation ASDU size supported by both devices.
|
|
* @see SE spec, sub-clause 5.3.8. */
|
|
/* 0x0501 to 0x05FF reserved */
|
|
|
|
|
|
/* Supply Limit Attribute Set, table D.31 */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_DEMAND_DELIVERED_ID = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_SUPPLY_LIMIT, 0x00), /**< @e CurrentDemandDelivered attribute represents
|
|
* the current Demand of Energy, Gas, or Water delivered at the premises. */
|
|
ZB_ZCL_ATTR_METERING_DEMAND_LIMIT_ID, /**< @e DemandLimit attribute reflects the current supply demand limit set in the meter. This value can be
|
|
* compared to the @ref ZB_ZCL_ATTR_METERING_CURRENT_DEMAND_DELIVERED_ID "CurrentDemandDelivered" attribute to
|
|
* understand if limits are being approached or exceeded. A value of 0xFFFFFF indicates demand limiting
|
|
* is switched off.*/
|
|
ZB_ZCL_ATTR_METERING_DEMAND_INTEGRATION_PERIOD_ID, /**< @e DemandIntegrationPeriod attribute is the number of minutes over which the
|
|
* @ref ZB_ZCL_ATTR_METERING_CURRENT_DEMAND_DELIVERED_ID "CurrentDemandDelivered" attribute is calculated. Valid
|
|
* range is 0x01 to 0xFF. 0x00 is a reserved value. */
|
|
ZB_ZCL_ATTR_METERING_NUMBER_OF_DEMAND_SUBINTERVALS_ID, /**< @e NumberOfDemandSubintervals attribute represents the number of subintervals used within the
|
|
* @ref ZB_ZCL_ATTR_METERING_DEMAND_INTEGRATION_PERIOD_ID "DemandIntegrationPeriod". The subinterval
|
|
* duration (in minutes) is obtained by dividing the @ref ZB_ZCL_ATTR_METERING_DEMAND_INTEGRATION_PERIOD_ID
|
|
* "DemandIntegrationPeriod" by the @ref ZB_ZCL_ATTR_METERING_NUMBER_OF_DEMAND_SUBINTERVALS_ID "NumberOfDemandSubintervals".
|
|
* The @ref ZB_ZCL_ATTR_METERING_CURRENT_DEMAND_DELIVERED_ID "CurrentDemandDelivered" attribute is updated at the
|
|
* each of each subinterval. Valid range is 0x01 to 0xFF. 0x00 is a reserved value. */
|
|
ZB_ZCL_ATTR_METERING_DEMAND_LIMIT_ARM_DURATION_ID, /**< @e DemandLimitArmDuration attribute defines the length of time, in seconds, that the supply shall be
|
|
* disconnected if the @ref ZB_ZCL_ATTR_METERING_DEMAND_LIMIT_ID "DemandLimit" attribute is enabled and
|
|
* the limit is exceeded.*/
|
|
ZB_ZCL_ATTR_METERING_LOAD_LIMIT_SUPPLY_STATE_ID, /**< @e LoadLimitSupplyState attribute indicates the required status of the supply once device is in a load
|
|
* limit state. @see SE 1.4 spec, table D.68. */
|
|
ZB_ZCL_ATTR_METERING_LOAD_LIMIT_COUNTER_ID, /**< @e LoadLimitCounter attribute is used for counting the number of times that the demand limit has
|
|
* exceeded the set threshold. */
|
|
ZB_ZCL_ATTR_METERING_SUPPLY_TAMPER_STATE_ID, /**< @e SupplyTamperState attribute indicates the required status of the supply following the detection of a
|
|
* tamper event within the metering device. @see SE 1.4 spec, table D.68. */
|
|
ZB_ZCL_ATTR_METERING_SUPPLY_DEPLETION_STATE_ID, /**< @e SupplyDepletionState attribute indicates the required status of the supply following detection of a
|
|
* depleted battery within the metering device. @see SE 1.4 spec, table D.68. */
|
|
ZB_ZCL_ATTR_METERING_SUPPLY_UNCONTROLLED_FLOW_STATE_ID, /**< @e SupplyUncontrolledFlowState attribute indicates the required status of the supply following detection
|
|
* of an uncontrolled flow event within the metering device. @see SE 1.4 spec, table D.68. */
|
|
/* 0x060A to 0x06FF reserved */
|
|
|
|
/*TODO: need to add set 0x07 - ZB_ZCL_METERING_SET_BLOCK_INFORMATION_DELIVERED*/
|
|
/*FIXME: Does we need to use _ID suffix in attributes? */
|
|
/*ZB_ZCL_METERING_SET_ALARMS attribute set*/
|
|
ZB_ZCL_ATTR_METERING_GENERIC_ALARM_MASK_ID = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_ALARMS, 0x00), /**< The AlarmMask attributes of the Alarm Attribute Set
|
|
* specify whether each of the alarms listed in the
|
|
* corresponding alarm group is enabled. When the bit number
|
|
* corresponding to the alarm number (minus the group offset) is set to 1,
|
|
* the alarm is enabled, else it is disabled. Bits not corresponding
|
|
* to a code in the respective table are reserved.
|
|
*/
|
|
ZB_ZCL_ATTR_METERING_ELECTRICITY_ALARM_MASK_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_GENERIC_ALARM_MASK_ID */
|
|
ZB_ZCL_ATTR_METERING_GENERIC_FLOW_PRESSURE_ALARM_MASK_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_GENERIC_ALARM_MASK_ID */
|
|
ZB_ZCL_ATTR_METERING_WATER_SPECIFIC_ALARM_MASK_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_GENERIC_ALARM_MASK_ID */
|
|
ZB_ZCL_ATTR_METERING_HEAT_AND_COOLING_SPECIFIC_ALARM_MASK_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_GENERIC_ALARM_MASK_ID */
|
|
ZB_ZCL_ATTR_METERING_GAS_SPECIFIC_ALARM_MASK_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_GENERIC_ALARM_MASK_ID */
|
|
ZB_ZCL_ATTR_METERING_EXTENDED_GENERIC_ALARM_MASK_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_GENERIC_ALARM_MASK_ID */
|
|
ZB_ZCL_ATTR_METERING_MANUFACTURER_ALARM_MASK_ID, /**< @copydoc ZB_ZCL_ATTR_METERING_GENERIC_ALARM_MASK_ID */
|
|
|
|
/*TODO: need to add set 0x09 */
|
|
|
|
/* Meter Billing Attribute Set, table D.44 */
|
|
|
|
/**< @e BillToDateDelivered provides a value for the costs in the current billing period.*/
|
|
ZB_ZCL_ATTR_METERING_BILL_TO_DATE_DELIVERED = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_METER_BILLING, 0x00),
|
|
ZB_ZCL_ATTR_METERING_BILL_TO_DATE_TIMESTAMP_DELIVERED, /**< @e BillToDateTimeStampDelivered The UTC timestamp
|
|
* when the associated BillToDateDelivered attribute was last updated.*/
|
|
ZB_ZCL_ATTR_METERING_PROJECTED_BILL_DELIVERED, /**< @e ProjectedBillDelivered provides a value indicating what the estimated state of the account
|
|
* will be at the end of the billing period based on past consumption.*/
|
|
ZB_ZCL_ATTR_METERING_PROJECTED_BILL_TIME_STAMP_DELIVERED, /**< @e ProjectedBillTimeStampDelivered
|
|
* The UTC timestamp when the associated ProjectedBillDelivered attribute was last updated. */
|
|
ZB_ZCL_ATTR_METERING_BILL_DELIVERED_TRAILING_DIGIT, /**< @e BillDeliveredTrailingDigit An 8-bit BitMap used to determine where the decimal point is located
|
|
* in the BillToDateDelivered and ProjectedBillDelivered attributes. */
|
|
ZB_ZCL_ATTR_METERING_BILL_TO_DATE_RECEIVED = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_METER_BILLING, 0x10),
|
|
/**< @e BillToDateReceived provides a value for the costs in the current billing period.
|
|
* This attribute is measured in a base unit of Currency with the decimal point located
|
|
* as indicated by the BillReceivedTrailingDigit attribute */
|
|
ZB_ZCL_ATTR_METERING_BILL_TO_DATE_TIMESTAMP_RECEIVED, /**< @e BillToDateTimeStampReceived The UTC timestamp
|
|
* when the associated BillToDateReceived attribute was last updated */
|
|
ZB_ZCL_ATTR_METERING_PROJECTED_BILL_RECEIVED, /**< @e ProjectedBillReceived provides a value indicating what the estimated state of the account
|
|
* will be at the end of the billing period based on past generation.*/
|
|
ZB_ZCL_ATTR_METERING_PROJECTED_BILL_TIME_STAMP_RECEIVED, /**< @e ProjectedBillTimeStampReceived
|
|
* The UTC timestamp when the associated ProjectedBillReceived attribute was last updated. */
|
|
ZB_ZCL_ATTR_METERING_BILL_RECEIVED_TRAILING_DIGIT, /**< @e BillReceivedTrailingDigit
|
|
* An 8-bit BitMap used to determine where the decimal point is located
|
|
* in the BillToDateReceived and ProjectedBillReceived attributes.*/
|
|
|
|
/* Supply Control Attribute, table D.45 */
|
|
|
|
/**< @e ProposedChangeSupplyImplementationTime indicates the time
|
|
* at which a proposed change to the supply is to be implemented.*/
|
|
ZB_ZCL_ATTR_METERING_PROPOSED_CHANGE_SUPPLY_IMPLEMENTATION_TIME = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_SUPPLY_CONTROL, 0x00),
|
|
ZB_ZCL_ATTR_METERING_PROPOSED_CHANGE_SUPPLY_STATUS, /**< @e ProposedChangeSupplyStatus indicates the proposed status of the supply
|
|
* once the change to the supply has be been implemented.*/
|
|
/**< @e UncontrolledFlowThreshold indicates the threshold above which a flow meter (e.g. Gas or Water)
|
|
* shall detect an uncontrolled flow.*/
|
|
ZB_ZCL_ATTR_METERING_UNCONTROLLED_FLOW_THRESHOLD = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_SUPPLY_CONTROL, 0x10),
|
|
ZB_ZCL_ATTR_METERING_UNCONTROLLED_FLOW_THRESHOLD_UNIT_OF_MEASURE, /**< @e UncontrolledFlowThresholdUnitOfMeasure indicates the unit of measure
|
|
* used in conjunction with the Uncontrolled Flow Threshold attribute.*/
|
|
ZB_ZCL_ATTR_METERING_UNCONTROLLED_FLOW_MULTIPLIER, /**< @e UncontrolledFlowMultiplier indicates the multiplier,
|
|
* to be used in conjunction with the Uncontrolled Flow Threshold and Uncontrolled Flow Divisor attributes,
|
|
* to determine the true flow threshold value.*/
|
|
ZB_ZCL_ATTR_METERING_UNCONTROLLED_FLOW_DIVISOR, /**< @e UncontrolledFlowDivisor
|
|
* The Uncontrolled Flow Divisor attribute indicates the divisor, to be used in conjunction
|
|
* with the Uncontrolled Flow Threshold and Uncontrolled Flow Multiplier attributes,
|
|
* to determine the true flow threshold value.*/
|
|
ZB_ZCL_ATTR_METERING_FLOW_STABILISATION_PERIOD, /**< @e FlowStabilisationPeriod indicates the time given to allow the flow to stabilize.*/
|
|
ZB_ZCL_ATTR_METERING_FLOW_MEASUREMENT_PERIOD, /**< @e FlowMeasurementPeriodAttribute indicates the period
|
|
* over which the flow is measured and compared against the Uncontrolled Flow Threshold attribute.*/
|
|
|
|
/* Alternative Historical Consumption Attribute Set, table D.46 */
|
|
/**< @e AlternativeInstantaneousDemand represents the current Demand delivered or received at the premises*/
|
|
ZB_ZCL_ATTR_METERING_ALT_INSTANTANEOUS_DEMAND = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_ALTERNATIVE_HISTORICAL_CONSUMPTION, 0x00),
|
|
ZB_ZCL_ATTR_METERING_CURRENT_DAY_ALT_CONSUMPTION_DELIVERED, /**< @e CurrentDayAlternativeConsumptionDelivered represents the summed value
|
|
* delivered to the premises since the Historical Freeze Time (HFT). */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_DAY_ALT_CONSUMPTION_RECEIVED, /**< @e CurrentDayAlternativeConsumptionReceived represents the summed value
|
|
* received from the premises since the Historical Freeze Time (HFT).*/
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY_ALT_CONSUMPTION_DELIVERED, /**< @e PreviousDayAlternativeConsumptionDelivered represents the summed value
|
|
* delivered to the premises within the previous 24 hour period
|
|
* starting at the alternative Historical Freeze Time (HFT).*/
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY_ALT_CONSUMPTION_RECEIVED, /**< @e PreviousDayAlternativeConsumptionReceived represents the summed value
|
|
* received to the premises within the previous 24 hour period
|
|
* starting at the alternative Historical Freeze Time (HFT).*/
|
|
ZB_ZCL_ATTR_METERING_CURRENT_ALT_PARTIAL_PROFILE_INTERVAL_START_TIME_DELIVERED, /**< @e CurrentAlternativePartialProfileIntervalStartTimeDelivered represents the start time
|
|
* of the current Load Profile interval being accumulated for commodity delivered */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_ALT_PARTIAL_PROFILE_INTERVAL_START_TIME_RECEIVED, /**< @e CurrentAlternativePartialProfileIntervalStartTimeReceived represents the start time
|
|
* of the current Load Profile interval being accumulated for commodity received */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_ALT_PARTIAL_PROFILE_INTERVAL_VALUE_DELIVERED, /**< @e CurrentAlternativePartialProfileIntervalValueDelivered represents the value
|
|
* * of the current Load Profile interval being accumulated for commodity delivered.*/
|
|
ZB_ZCL_ATTR_METERING_CURRENT_ALT_PARTIAL_PROFILE_INTERVAL_VALUE_RECEIVED, /**< @e CurrentAlternativePartialProfileIntervalValueReceived represents the value
|
|
* * of the current Load Profile interval being accumulated for commodity received .*/
|
|
ZB_ZCL_ATTR_METERING_CURRENT_DAY_ALT_MAX_PRESSURE, /**< @e CurrentDayAlternativeMaxPressure is the maximum pressure
|
|
* reported during a day from the water or gas meter. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_DAY_ALT_MIN_PRESSURE, /**< @e CurrentDayAlternativeMinPressure is the minimum pressure
|
|
* reported during a day from the water or gas meter. */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY_ALT_MAX_PRESSURE, /**< @e PreviousDayAlternativeMaxPressure represents the maximum pressure
|
|
* reported during previous day from the water or gas meter.*/
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY_ALT_MIN_PRESSURE, /**< @e PreviousDayAlternativeMinPressure represents the minimum pressure
|
|
* reported during previous day from the water or gas meter.*/
|
|
|
|
ZB_ZCL_ATTR_METERING_CURRENT_DAY_ALT_MAX_DEMAND, /**< @e CurrentDayAlternativeMaxDemand represents the maximum demand or rate
|
|
* of delivered value of Energy, Gas, or Water being utilized at the premises.*/
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY_ALT_MAX_DEMAND, /**< @e PreviousDayAlternativeMaxDemand represents represents the maximum demand or rate
|
|
* of delivered value of Energy, Gas, or Water being utilized at the premises.*/
|
|
|
|
ZB_ZCL_ATTR_METERING_CURRENT_MONTH_ALT_MAX_DEMAND, /**< @e CurrentMonthAlternativeMaxDemand is the maximum demand reported during a month from the meter. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_YEAR_ALT_MAX_DEMAND, /**< @e CurrentYearAlternativeMaxDemand is the maximum demand reported during a year from the meter.*/
|
|
|
|
/**< @e PreviousDayNAlternativeConsumptionDelivered represents the summed value delivered to the premises
|
|
* within the previous 24 hour period starting at the Historical Freeze Time (HFT). */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY2_ALT_CONSUMPTION_DELIVERED = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_ALTERNATIVE_HISTORICAL_CONSUMPTION, 0x20),
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_DAY2_ALT_CONSUMPTION_RECEIVED, /**< @e PreviousDayNAlternativeConsumptionReceived
|
|
* represents the summed value received from the premises
|
|
* within the previous 24 hour period starting at the Historical Freeze Time (HFT).*/
|
|
|
|
/**< @e CurrentWeekAlternativeConsumptionDelivered represents the summed value
|
|
* delivered to the premises since the Historical Freeze Time (HFT) on Monday to the last HFT read. */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_WEEK_ALT_CONSUMPTION_DELIVERED = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_ALTERNATIVE_HISTORICAL_CONSUMPTION, 0x30),
|
|
ZB_ZCL_ATTR_METERING_CURRENT_WEEK_ALT_CONSUMPTION_RECEIVED, /**< @e CurrentWeekAlternativeConsumptionReceived represents the summed value
|
|
* received from the premises since the Historical Freeze Time (HFT) on Monday to the last HFT read */
|
|
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK_ALT_CONSUMPTION_DELIVERED, /**< @e PreviousWeekNAlternativeConsumptionDelivered represents the summed value
|
|
* delivered to the premises within the previous week period
|
|
* starting at the Historical Freeze Time (HFT) on the Monday to the Sunday. */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_WEEK_ALT_CONSUMPTION_RECEIVED, /**< @e PreviousWeekNAlternativeConsumptionReceived represents the summed value
|
|
* received from the premises within the previous week period
|
|
* starting at the Historical Freeze Time (HFT) on the Monday to the Sunday*/
|
|
/**< @e CurrentMonthAlternativeConsumptionDelivered represents the summed value delivered to the premises
|
|
* since the Historical Freeze Time (HFT) on the 1st of the month to the last HFT read */
|
|
ZB_ZCL_ATTR_METERING_CURRENT_MONTH_ALT_CONSUMPTION_DELIVERED = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_ALTERNATIVE_HISTORICAL_CONSUMPTION, 0x40),
|
|
ZB_ZCL_ATTR_METERING_CURRENT_MONTH_ALT_CONSUMPTION_RECEIVED, /**< @e CurrentMonthAlternativeConsumptionReceived represents the summed value
|
|
* received from the premises since the Historical Freeze Time (HFT)
|
|
* on the 1st of the month to the last HFT read. */
|
|
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_ALT_CONSUMPTION_DELIVERED, /**< @e PreviousMonthNAlternativeConsumptionDelivered represents the summed value
|
|
* delivered to the premises within the previous Month period
|
|
* starting at the Historical Freeze Time (HFT) on the 1st of the month to the last day of the month. */
|
|
ZB_ZCL_ATTR_METERING_PREVIOUS_MONTH_ALT_CONSUMPTION_RECEIVED, /**< @e PreviousMonthNAlternativeConsumptionReceived represents the summed value
|
|
* received from the premises within the previous month period
|
|
* starting at the Historical Freeze Time (HFT) on the 1st of the month to the last day of the month. */
|
|
|
|
/* ZB_ZCL_METERING_SET_FOUR_QUADRANT_ELECTRICITY attribute set */
|
|
/*NOTE: the first attribute from this attribute set starts from 0x0D01 value instead of 0x0D00 */
|
|
/*NOTE: attribute 0x0D04 in one spec it is ZB_ZCL_ATTR_METERING_CURRENT_ACTIVE_SUMMATION_Q4_ID,
|
|
in another it is ZB_ZCL_ATTR_METERING_CURRENT_REACTIVE_SUMMATION_Q1_ID
|
|
NOTE: It is supposed that ZB_ZCL_ATTR_METERING_CURRENT_ACTIVE_SUMMATION_Q1_ID = 0x0D00
|
|
*/
|
|
ZB_ZCL_ATTR_METERING_CURRENT_ACTIVE_SUMMATION_Q1_ID = ZB_ZCL_ATTR_SET_WITH_ATTR_ID(ZB_ZCL_METERING_SET_FOUR_QUADRANT_ELECTRICITY, 0x01), /**< This attribute represents the most
|
|
* recent summed value of Active Energy (kWh)
|
|
* delivered in the quadrant Q1.
|
|
*/
|
|
ZB_ZCL_ATTR_METERING_CURRENT_ACTIVE_SUMMATION_Q2_ID, /**< This attribute represents the most
|
|
* recent summed value of Active Energy (kWh)
|
|
* delivered in the quadrant Q2.
|
|
*/
|
|
ZB_ZCL_ATTR_METERING_CURRENT_ACTIVE_SUMMATION_Q3_ID, /**< This attribute represents the most
|
|
* recent summed value of Active Energy (kWh)
|
|
* delivered in the quadrant Q3.
|
|
*/
|
|
ZB_ZCL_ATTR_METERING_CURRENT_ACTIVE_SUMMATION_Q4_ID, /**< This attribute represents the most
|
|
* recent summed value of Active Energy (kWh)
|
|
* delivered in the quadrant Q4.
|
|
*/
|
|
ZB_ZCL_ATTR_METERING_CURRENT_REACTIVE_SUMMATION_Q1_ID, /**< This attribute represents the most recent
|
|
* summed value of Reactive Energy (kVarh) delivered
|
|
* in quadrant Q1.
|
|
*/
|
|
ZB_ZCL_ATTR_METERING_CURRENT_REACTIVE_SUMMATION_Q2_ID, /**< This attribute represents the most recent
|
|
* summed value of Reactive Energy (kVarh) delivered
|
|
* in quadrant Q2.
|
|
*/
|
|
ZB_ZCL_ATTR_METERING_CURRENT_REACTIVE_SUMMATION_Q3_ID, /**< This attribute represents the most recent
|
|
* summed value of Reactive Energy (kVarh) delivered
|
|
* in quadrant Q3.
|
|
*/
|
|
ZB_ZCL_ATTR_METERING_CURRENT_REACTIVE_SUMMATION_Q4_ID /**< This attribute represents the most recent
|
|
* summed value of Reactive Energy (kVarh) delivered
|
|
* in quadrant Q4.
|
|
*/
|
|
};
|
|
|
|
|
|
/** @brief @e CurrentBlock attribute values
|
|
* @see @ref ZB_ZCL_ATTR_METERING_CURRENT_BLOCK_ID
|
|
* @see SE 1.4 spec, Table D.12.
|
|
*/
|
|
enum zb_zcl_metering_block_e
|
|
{
|
|
ZB_ZCL_METERING_BLOCK_NOT_USED = 0x00, /**< No blocks in use */
|
|
ZB_ZCL_METERING_BLOCK_1 = 0x01, /**< Block 1 */
|
|
ZB_ZCL_METERING_BLOCK_2 = 0x02, /**< Block 2 */
|
|
ZB_ZCL_METERING_BLOCK_3 = 0x03, /**< Block 3 */
|
|
ZB_ZCL_METERING_BLOCK_4 = 0x04, /**< Block 4 */
|
|
ZB_ZCL_METERING_BLOCK_5 = 0x05, /**< Block 5 */
|
|
ZB_ZCL_METERING_BLOCK_6 = 0x06, /**< Block 6 */
|
|
ZB_ZCL_METERING_BLOCK_7 = 0x07, /**< Block 7 */
|
|
ZB_ZCL_METERING_BLOCK_8 = 0x08, /**< Block 8 */
|
|
ZB_ZCL_METERING_BLOCK_9 = 0x09, /**< Block 9 */
|
|
ZB_ZCL_METERING_BLOCK_10 = 0x0A, /**< Block 10 */
|
|
ZB_ZCL_METERING_BLOCK_11 = 0x0B, /**< Block 11 */
|
|
ZB_ZCL_METERING_BLOCK_12 = 0x0C, /**< Block 12 */
|
|
ZB_ZCL_METERING_BLOCK_13 = 0x0D, /**< Block 13 */
|
|
ZB_ZCL_METERING_BLOCK_14 = 0x0E, /**< Block 14 */
|
|
ZB_ZCL_METERING_BLOCK_15 = 0x0F, /**< Block 15 */
|
|
ZB_ZCL_METERING_BLOCK_16 = 0x10, /**< Block 16 */
|
|
/* 0x11 to 0xFF reserved */
|
|
};
|
|
|
|
|
|
/** @brief @e SupplyStatus attribute values
|
|
* @see @ref ZB_ZCL_ATTR_METERING_SUPPLY_STATUS_ID
|
|
* @see SE 1.4 spec, table D.13.
|
|
*/
|
|
enum zb_zcl_metering_supply_status_e
|
|
{
|
|
ZB_ZCL_SUPPLY_STATUS_OFF = 0x00, /**< Supply OFF */
|
|
ZB_ZCL_SUPPLY_STATUS_ARMED = 0x01, /**< Supply OFF/ARMED */
|
|
ZB_ZCL_SUPPLY_STATUS_ON = 0x02 /**< Supply ON */
|
|
/* 0x03 to 0xFF reserved for future use */
|
|
};
|
|
|
|
|
|
/** @brief Bit mapping of the @e Status attribute (Electricity)
|
|
* @see @ref ZB_ZCL_ATTR_METERING_STATUS_ID
|
|
* @see SE spec, subclause 3.2.2.3.1, table D.16.
|
|
*/
|
|
enum zb_zcl_metering_status_electricity_e
|
|
{
|
|
ZB_ZCL_METERING_ELECTRICITY_CHECK_METER = 1 << 0, /**< @e CheckMeter bit is set to true when a non fatal problem has been detected on the meter such as
|
|
* a measurement error, memory error, self check error. */
|
|
ZB_ZCL_METERING_ELECTRICITY_LOW_BATTERY = 1 << 1, /**< @e LowBattery bit is set to true when the battery needs maintenance. */
|
|
ZB_ZCL_METERING_ELECTRICITY_TAMPER_DETECT = 1 << 2, /**< @e TamperDetect bit is set to true if a tamper event has been detected. */
|
|
ZB_ZCL_METERING_ELECTRICITY_POWER_FAILURE = 1 << 3, /**< @e PowerFailure bit is set to true during a power outage. */
|
|
ZB_ZCL_METERING_ELECTRICITY_POWER_QUALITY = 1 << 4, /**< @e PowerQuality bit is set to true if a power quality event has been detected such as a low
|
|
* voltage, high voltage. */
|
|
ZB_ZCL_METERING_ELECTRICITY_LEAK_DETECT = 1 << 5, /**< @e LeakDetect bit is set to true when a leak has been detected. */
|
|
ZB_ZCL_METERING_ELECTRICITY_SERVICE_DISCONNECT_OPEN = 1 << 6, /**< @e ServiceDisconnectOpen bit is Set to true when the service has been disconnected to this premises. */
|
|
ZB_ZCL_METERING_ELECTRICITY_RESERVED = 1 << 7 /**< Reserved bit */
|
|
};
|
|
|
|
|
|
/** @brief Bit mapping of the @e Status attribute (Gas)
|
|
* @see @ref ZB_ZCL_ATTR_METERING_STATUS_ID
|
|
* @see SE spec, subclause 3.2.2.3.1, table D.17.
|
|
*/
|
|
enum zb_zcl_metering_status_gas_e
|
|
{
|
|
ZB_ZCL_METERING_GAS_CHECK_METER = 1 << 0, /**< @e CheckMeter bit is Set to true when a non fatal problem has been detected on the meter such as
|
|
* a measurement error, memory error, or self check error. */
|
|
ZB_ZCL_METERING_GAS_LOW_BATTERY = 1 << 1, /**< @e LowBattery bit is set to true when the battery needs maintenance. */
|
|
ZB_ZCL_METERING_GAS_TAMPER_DETECT = 1 << 2, /**< @e TamperDetect bit is set to true if a tamper event has been detected. */
|
|
ZB_ZCL_METERING_GAS_RESERVED = 1 << 3, /**< Reserved bit */
|
|
ZB_ZCL_METERING_GAS_LOW_PRESSURE = 1 << 4, /**< @e LowPressure bit is set to true when the pressure at the meter is below the meter's low
|
|
* pressure threshold value. */
|
|
ZB_ZCL_METERING_GAS_LEAK_DETECT = 1 << 5, /**< @e LeakDetect bit is set to true when a leak has been detected. */
|
|
ZB_ZCL_METERING_GAS_SERVICE_DISCONNECT = 1 << 6, /**< @e ServiceDisconnect bit is set to true when the service has been disconnected to this premises.
|
|
* Ex. The valve is in the closed position preventing delivery of gas. */
|
|
ZB_ZCL_METERING_GAS_REVERSE_FLOW = 1 << 7 /**< @e ReverseFlow bit is set to true if flow detected in the opposite direction to normal (from
|
|
* consumer to supplier). */
|
|
};
|
|
|
|
|
|
/** @brief Bit mapping of the @e Status attribute (Water)
|
|
* @see @ref ZB_ZCL_ATTR_METERING_STATUS_ID
|
|
* @see SE 1.4 spec, subclause 3.2.2.3.1, table D.18.
|
|
*/
|
|
enum zb_zcl_metering_status_water_e
|
|
{
|
|
ZB_ZCL_METERING_WATER_CHECK_METER = 1 << 0, /**< @e CheckMeter bit is Set to true when a non fatal problem has been detected on the meter such as
|
|
* a measurement error, memory error, or self check error. */
|
|
ZB_ZCL_METERING_WATER_LOW_BATTERY = 1 << 1, /**< @e LowBattery bit is set to true when the battery needs maintenance. */
|
|
ZB_ZCL_METERING_WATER_TAMPER_DETECT = 1 << 2, /**< @e TamperDetect bit set to true if a tamper event has been detected. */
|
|
ZB_ZCL_METERING_WATER_PIPE_EMTPY = 1 << 3, /**< @e PipeEmpty bit is set to true when the service pipe at the meter is empty and there is no flow
|
|
* in either direction. */
|
|
ZB_ZCL_METERING_WATER_LOW_PRESSURE = 1 << 4, /**< @e LowPressure bit is Set to true when the pressure at the meter is below the meter's low
|
|
* pressure threshold value. */
|
|
ZB_ZCL_METERING_WATER_LEAK_DETECT = 1 << 5, /**< @e LeakDetect bit is set to true when a leak has been detected. */
|
|
ZB_ZCL_METERING_WATER_SERVICE_DISCONNECT = 1 << 6, /**< @e ServiceDisconnect bit is set to true when the service has been disconnected to this premises.
|
|
* Ex. The valve is in the closed position preventing delivery of water. */
|
|
ZB_ZCL_METERING_WATER_REVERSE_FLOW = 1 << 7 /**< @e ReverseFlow bit is Set to true if flow detected in the opposite direction to normal (from
|
|
* consumer to supplier). */
|
|
};
|
|
|
|
|
|
/** @brief Bit mapping of the @e Status attribute (Heat and Cooling)
|
|
* @see @ref ZB_ZCL_ATTR_METERING_STATUS_ID
|
|
* @see SE 1.4 spec, subclause 3.2.2.3.1, table D.19.
|
|
*/
|
|
enum zb_zcl_metering_status_heat_cooling_e
|
|
{
|
|
ZB_ZCL_METERING_HCOOL_CHECK_METER = 1 << 0, /**< @e CheckMeter bit is Set to true when a non fatal problem has been detected on the meter such
|
|
* as a measurement error, memory error, or self check error. */
|
|
ZB_ZCL_METERING_HCOOL_LOW_BATTERY = 1 << 1, /**< @e LowBattery bit is set to true when the battery needs maintenance. */
|
|
ZB_ZCL_METERING_HCOOL_TAMPER_DETECT = 1 << 2, /**< @e TamperDetect bit is set to true if a tamper event has been detected. */
|
|
ZB_ZCL_METERING_HCOOL_TEMPERATURE_SENSOR = 1 << 3, /**< @e TemperatureSensor bit is Set to true when an error is detected on a temperature sensor at
|
|
* this premises. */
|
|
ZB_ZCL_METERING_HCOOL_BURST_DETECT = 1 << 4, /**< @e BurstDetect bit is set to true when a burst is detected on pipes at this premises. */
|
|
ZB_ZCL_METERING_HCOOL_LEAK_DETECT = 1 << 5, /**< @e LeakDetect bit is set to true when a leak has been detected. */
|
|
ZB_ZCL_METERING_HCOOL_SERVICE_DISCONNECT = 1 << 6, /**< @e ServiceDisconnect bit is Set to true when the service has been disconnected to this premises.
|
|
* Ex. The valve is in the closed position preventing delivery of heat or cooling. */
|
|
ZB_ZCL_METERING_HCOOL_FLOW_SENSOR = 1 << 7 /**< @e FlowSensor bit is set to true when an error is detected on a flow sensor at this premises. */
|
|
};
|
|
|
|
|
|
/** @brief Bit mapping of the @e ExtendedStatus attribute (General Flags)
|
|
* @see @ref ZB_ZCL_ATTR_METERING_EXTENDED_STATUS_ID
|
|
* @see SE 1.4 spec, subclause D.3.2.2.3.5, table D.20
|
|
*/
|
|
enum zb_zcl_metering_extstatus_general_e
|
|
{
|
|
ZB_ZCL_METERING_METER_COVER_REMOVED = 1 << 0, /**< @e MeterCoverRemoved bit is set to true when the device detects the meter
|
|
* cover being removed. */
|
|
ZB_ZCL_METERING_STRONG_MAGNETIC_FIELD_DETECTED = 1 << 1, /**< @e StrongMagneticFieldDetected bit is set to true when the device detects
|
|
* presence of a strong magnetic field */
|
|
ZB_ZCL_METERING_BATTERY_FAILURE = 1 << 2, /**< @e BatteryFailure bit is set to true when the device detects that its battery
|
|
* has failed. */
|
|
ZB_ZCL_METERING_PROGRAM_MEMORY_ERROR = 1 << 3, /**< @e ProgramMemoryError bit is set to true when the device detects an error
|
|
* within its program (non-volatile) memory. */
|
|
ZB_ZCL_METERING_RAM_ERROR = 1 << 4, /**< @e RAMError bit is set to true when the device detects an instance of a
|
|
* Random Access Memory error within the device memory. */
|
|
ZB_ZCL_METERING_NV_MEMORY_ERROR = 1 << 5, /**< @e NVMemoryError bit is set to true when the device detects an instance of a
|
|
* Non Volatile memory error within the device memory - this is a fatal meter
|
|
* error that will require the meter replacement */
|
|
ZB_ZCL_METERING_MEASUREMENT_SYSTEM_ERROR = 1 << 6, /**< @e MeasurementSystemError bit is set to true when the device detects an error
|
|
* within its measurement system. */
|
|
ZB_ZCL_METERING_WATCHDOG_ERROR = 1 << 7, /**< @e WatchdogError bit is set to true when the device has detected an instance
|
|
* of a watchdog reset event (following a catastrophic fault within the device). */
|
|
ZB_ZCL_METERING_SUPPLY_DISCONNECT_FAILURE = 1 << 8, /**< @e SupplyDisconnectFailure bit is set to true when the device has detected
|
|
* that the valve has not closed as expected (for gas) or the contactor has not
|
|
* opened as expected (for electricity). */
|
|
ZB_ZCL_METERING_SUPPLY_CONNECT_FAILURE = 1 << 9, /**< @e SupplyConnectFailure bit is set to true when the device has detected that
|
|
* the valve has not opened as expected (for gas) or the contactor has not closed
|
|
* as expected (for electricity). */
|
|
ZB_ZCL_METERING_MEASUREMENT_SW_CHANGED = 1 << 10, /**< @e MeasurementSWChanged/Tampered bit is set to true when the device detects that
|
|
* its measurement software has changed. */
|
|
ZB_ZCL_METERING_CLOCK_INVALID = 1 << 11, /**< @e ClockInvalid bit is set to true when the device detects that its internal clock
|
|
* is invalid. */
|
|
ZB_ZCL_METERING_TEMPERATURE_EXCEEDED = 1 << 12, /**< @e TemperatureExceeded bit is set to true when the metering device's temperature
|
|
* exceeds a predefined limit. There are various reasons for temperature rise in
|
|
* metering devices. */
|
|
ZB_ZCL_METERING_MOISTURE_DETECTED = 1 << 13 /**< @e MoistureDetected bit is set to true when a sensor has detected the presence of
|
|
* moisture e.g. moisture in a gas line which can cause a drop in gas pressure, or
|
|
* moisture detected in the sealed component area within a water meter. */
|
|
/* bits 14-23 reserved */
|
|
};
|
|
|
|
|
|
/** @brief Bit mapping of the @e ExtendedStatus attribute (Electricity Meter specific Flags)
|
|
* @see @ref ZB_ZCL_ATTR_METERING_EXTENDED_STATUS_ID
|
|
* @see SE 1.4 spec, subclause D.3.2.2.3.5, table D.21
|
|
*/
|
|
enum zb_zcl_metering_extstatus_electricity_e
|
|
{
|
|
ZB_ZCL_METERING_ELECTRICITY_TERMINAL_COVER_REMOVED = 1L << 24, /**< @e TerminalCoverRemoved bit is set to true when the device detects that its
|
|
* terminal cover has been removed. */
|
|
ZB_ZCL_METERING_ELECTRICITY_INCORRECT_POLARITY = 1L << 25, /**< @e IncorrectPolarity bit is set to true when the electricity meter detects
|
|
* incorrect polarity on the electricity supply. */
|
|
ZB_ZCL_METERING_ELECTRICITY_CURRENT_WITH_NO_VOLTAGE = 1L << 26, /**< @e CurrentWithNoVoltage bit is set to true when the meter has been tampered
|
|
* with, to disconnect the measurement function from the supply. Electricity is
|
|
* still flowing but not being recorded. */
|
|
ZB_ZCL_METERING_ELECTRICITY_LIMIT_THRESHOLD_EXCEEDED = 1L << 27, /**< @e LimitThresholdExceeded bit is set to true when the electricity meter detects
|
|
* that the load has exceeded the load limit threshold. */
|
|
ZB_ZCL_METERING_ELECTRICITY_UNDER_VOLTAGE = 1L << 28, /**< @e UnderVoltage bit is set to true when the electricity meter indicates that
|
|
* the voltage measurement over the voltage measurement period is lower than the
|
|
* voltage threshold. */
|
|
ZB_ZCL_METERING_ELECTRICITY_OVER_VOLTAGE = 1L << 29, /**< @e OverVoltage bit is set to true when the electricity meter indicates that the
|
|
* voltage measurement over the voltage measurement period is higher than the
|
|
* voltage threshold. */
|
|
ZB_ZCL_METERING_ELECTRICITY_BIDIRECTION_OPERATION = 1L << 30, /**<Set to true when the meter is capable of measuring energy in both directions
|
|
* (i.e. delivered and received). */
|
|
/*Each enumerator that appears in the body of an enumeration specifier becomes an integer constant with type int in the enclosing scope.*/
|
|
ZB_ZCL_METERING_ELECTRICITY_ACTIVE_POWER_RECEIVED = -2147483648LL /**< Set to true when active power flows in the received direction
|
|
* (generation from the premises to the grid). */
|
|
/* bits 32-63 reserved */
|
|
};
|
|
|
|
|
|
/** @brief Bit mapping of the @e ExtendedStatus attribute (Gas Meter specific Flags)
|
|
* @see @ref ZB_ZCL_ATTR_METERING_EXTENDED_STATUS_ID
|
|
* @see SE 1.4 spec, subclause D.3.2.2.3.5, table D.22
|
|
*/
|
|
enum zb_zcl_metering_extstatus_gas_e
|
|
{
|
|
ZB_ZCL_METERING_GAS_BATTERY_COVER_REMOVED = 1L << 24, /**< @e BatteryCoverRemoved bit is set to true when the gas meter detects that its
|
|
* battery cover has been removed. */
|
|
ZB_ZCL_METERING_GAS_TILT_TAMPER = 1L << 25, /**< @e TiltTamper bit is set to true when the meter detects a change in its physical
|
|
* properties (i.e. that it is being tilted, the tilt sensor has been activated or
|
|
* otherwise tampered with). */
|
|
ZB_ZCL_METERING_GAS_EXCESS_FLOW = 1L << 26 /**< @e ExcessFlow bit is set to true when the gas meter detects excess flow (e.g. when
|
|
* local supply restoration is attempted). */
|
|
/* bits 26-63 reserved */
|
|
};
|
|
|
|
|
|
/** @brief @e LowMediumHighStatus Attribute values
|
|
* @see @ref ZB_ZCL_ATTR_METERING_AMBIENT_CONSUMPTION_INDICATOR_ID
|
|
* @see SE 1.4 spec, table D.23.
|
|
*/
|
|
enum zb_zcl_metering_low_medium_high_status_e
|
|
{
|
|
ZB_ZCL_METERING_STATUS_LOW = 0x00, /**< Low energy usage */
|
|
ZB_ZCL_METERING_STATUS_MEDIUM = 0x01, /**< Medium energy usage */
|
|
ZB_ZCL_METERING_STATUS_HIGH = 0x02, /**< High energy usage */
|
|
};
|
|
|
|
|
|
/** @brief @e UnitOfMeasure Attribute values
|
|
* @see @ref ZB_ZCL_ATTR_METERING_UNIT_OF_MEASURE_ID
|
|
@see SE 1.4 spec, subclause 3.2.2.4.1, table D.26
|
|
*/
|
|
enum zb_zcl_metering_unit_of_measure_e
|
|
{
|
|
ZB_ZCL_METERING_UNIT_KW_KWH_BINARY = 0x00, /**< kW, kWh binary value */
|
|
ZB_ZCL_METERING_UNIT_M3_M3H_BINARY = 0x01, /**< m3, m3/h binary value */
|
|
ZB_ZCL_METERING_UNIT_FT3_FT3H_BINARY = 0x02, /**< ft3, ft3/h binary value */
|
|
ZB_ZCL_METERING_UNIT_CCF_CCFH_BINARY = 0x03, /**< ccf, ccf/h binary value */
|
|
ZB_ZCL_METERING_UNIT_USGL_USGLH_BINARY = 0x04, /**< US gl, US gl/h binary value */
|
|
ZB_ZCL_METERING_UNIT_IMPGL_IMPGLH_BINARY = 0x05, /**< IMP gl, IMP gl/h binary value */
|
|
ZB_ZCL_METERING_UNIT_BTU_BTUH_BINARY = 0x06, /**< BTU, BTU/h binary value */
|
|
ZB_ZCL_METERING_UNIT_L_LH_BINARY = 0x07, /**< l, l/h binary value */
|
|
ZB_ZCL_METERING_UNIT_KPAG_BINARY = 0x08, /**< kPA (gauge) binary value */
|
|
ZB_ZCL_METERING_UNIT_KPAA_BINARY = 0x09, /**< kPA (absolute) binary value */
|
|
ZB_ZCL_METERING_UNIT_MCF_MCFH_BINARY = 0x0A, /**< mcf, mcf/h binary value */
|
|
ZB_ZCL_METERING_UNIT_UNITLESS_BINARY = 0x0B, /**< Unitless binary value */
|
|
ZB_ZCL_METERING_UNIT_MJ_MJS_BINARY = 0x0C, /**< MJ, MJ/h binary value */
|
|
ZB_ZCL_METERING_UNIT_KVAR_KVARH_BINARY = 0x0D, /**< kVar, kVar/h binary value */
|
|
|
|
ZB_ZCL_METERING_UNIT_BINARY_RESERVED = 0x0E, /**< 0x0E to 0x7F reserved for future use */
|
|
|
|
|
|
ZB_ZCL_METERING_UNIT_KW_KWH_BCD = 0x80, /**< kW, kWh BCD value */
|
|
ZB_ZCL_METERING_UNIT_M3_M3H_BCD = 0x81, /**< m3, m3/h BCD value */
|
|
ZB_ZCL_METERING_UNIT_FT3_FT3H_BCD = 0x82, /**< ft3, ft3/h BCD value */
|
|
ZB_ZCL_METERING_UNIT_CCF_CCFH_BCD = 0x83, /**< ccf, ccf/h BCD value */
|
|
ZB_ZCL_METERING_UNIT_USGL_USGLH_BCD = 0x84, /**< US gl, US gl/h BCD value */
|
|
ZB_ZCL_METERING_UNIT_IMPGL_IMPGLH_BCD = 0x85, /**< IMP gl, IMP gl/h BCD value */
|
|
ZB_ZCL_METERING_UNIT_BTU_BTUH_BCD = 0x86, /**< BTU, BTU/h BCD value */
|
|
ZB_ZCL_METERING_UNIT_L_LH_BCD = 0x87, /**< l, l/h BCD value */
|
|
ZB_ZCL_METERING_UNIT_KPAG_BCD = 0x88, /**< kPA (gauge) BCD value */
|
|
ZB_ZCL_METERING_UNIT_KPAA_BCD = 0x89, /**< kPA (absolute) BCD value */
|
|
ZB_ZCL_METERING_UNIT_MCF_MCFH_BCD = 0x8A, /**< mcf, mcf/h BCD value */
|
|
ZB_ZCL_METERING_UNIT_UNITLESS_BCD = 0x8B, /**< Unitless BCD value */
|
|
ZB_ZCL_METERING_UNIT_MJ_MJS_BCD = 0x8C, /**< MJ, MJ/h BCD value */
|
|
ZB_ZCL_METERING_UNIT_KVAR_KVARH_BCD = 0x8D, /**< kVar, kVar/h BCD value */
|
|
|
|
ZB_ZCL_METERING_UNIT_BCD_RESERVED = 0x8E /**< 0x8E to 0xFF reserved for future use */
|
|
};
|
|
|
|
|
|
/** @brief @e DeviceType Attribute values
|
|
* @see @ref ZB_ZCL_ATTR_METERING_METERING_DEVICE_TYPE_ID
|
|
* @see SE 1.4 spec, subclause 3.2.2.4.7, table D.27
|
|
*/
|
|
enum zb_zcl_metering_device_type_e
|
|
{
|
|
ZB_ZCL_METERING_ELECTRIC_METERING = 0, /**< Electric metering device */
|
|
ZB_ZCL_METERING_GAS_METERING = 1, /**< Gas metering device */
|
|
ZB_ZCL_METERING_WATER_METERING = 2, /**< Water metering device */
|
|
ZB_ZCL_METERING_PRESSURE_METERING = 4, /**< Pressure metering device */
|
|
ZB_ZCL_METERING_HEAT_METERING = 5, /**< Heat metering device */
|
|
ZB_ZCL_METERING_COOLING_METERING = 6, /**< Cooling metering device */
|
|
ZB_ZCL_METERING_EUMD = 7, /**< End Use Measurement Device (EUMD) for metering electric vehicle charging */
|
|
ZB_ZCL_METERING_PV_GENERATION_METERING = 8, /**< PV Generation Metering device */
|
|
ZB_ZCL_METERING_WIND_TURBINE_GENERATION_METERING = 9, /**< Wind Turbine Generation Metering device */
|
|
ZB_ZCL_METERING_WATER_TURBINE_GENERATION_METERING = 10, /**< Water Turbine Generation Metering device */
|
|
ZB_ZCL_METERING_MICRO_GENERATION_METERING = 11, /**< Micro Generation Metering device */
|
|
ZB_ZCL_METERING_SOLAR_HOT_WATER_GENERATION_METERING = 12, /**< Solar Hot Water Generation Metering device */
|
|
ZB_ZCL_METERING_ELECTRIC_METERING_ELEMENT_PHASE1 = 13, /**< Electric Metering Element/Phase 1 */
|
|
ZB_ZCL_METERING_ELECTRIC_METERING_ELEMENT_PHASE2 = 14, /**< Electric Metering Element/Phase 2 */
|
|
ZB_ZCL_METERING_ELECTRIC_METERING_ELEMENT_PHASE3 = 15, /**< Electric Metering Element/Phase 3 */
|
|
/* 16 to 126 reserved for future growth */
|
|
|
|
|
|
ZB_ZCL_METERING_MIRRORED_ELECTRIC_METERING = 127, /**< Mirrored Electric Metering device */
|
|
ZB_ZCL_METERING_MIRRORED_GAS_METERING = 128, /**< Mirrored Gas Metering device */
|
|
ZB_ZCL_METERING_MIRRORED_WATER_METERING = 129, /**< Mirrored Water Metering device */
|
|
/* 130 == Mirrored Thermal Metering (deprecated) */
|
|
ZB_ZCL_METERING_MIRRORED_PRESSURE_METERING = 131, /**< Mirrored Pressure Metering device */
|
|
ZB_ZCL_METERING_MIRRORED_HEAT_METERING = 132, /**< Mirrored Heat Metering device */
|
|
ZB_ZCL_METERING_MIRRORED_COOLING_METERING = 133, /**< Mirrored Cooling Metering device */
|
|
ZB_ZCL_METERING_MIRRORED_EUMD = 134, /**< Mirrored End Use Measurement Device (EUMD) for metering electric vehicle charging */
|
|
ZB_ZCL_METERING_MIRRORED_PV_GENERATION_METERING = 135, /**< Mirrored PV Generation Metering device */
|
|
ZB_ZCL_METERING_MIRRORED_WIND_TURBINE_GENERATION_METERING = 136, /**< Mirrored Wind Turbine Generation Metering device */
|
|
ZB_ZCL_METERING_MIRRORED_WATER_TURBINE_GENERATION_METERING = 137, /**< Mirrored Water Turbine Generation Metering device */
|
|
ZB_ZCL_METERING_MIRRORED_MICRO_GENERATION_METERING = 138, /**< Mirrored Micro Generation Metering device */
|
|
ZB_ZCL_METERING_MIRRORED_SOLAR_HOT_WATER_GENERATION_METERING = 139, /**< Mirrored Solar Hot Water Generation Metering device */
|
|
ZB_ZCL_METERING_MIRRORED_ELECTRIC_METERING_ELEMENT_PHASE1 = 140, /**< Mirrored Electric Metering Element/Phase 1 */
|
|
ZB_ZCL_METERING_MIRRORED_ELECTRIC_METERING_ELEMENT_PHASE2 = 141, /**< Mirrored Electric Metering Element/Phase 2 */
|
|
ZB_ZCL_METERING_MIRRORED_ELECTRIC_METERING_ELEMENT_PHASE3 = 142, /**< Mirrored Electric Metering Element/Phase 3 */
|
|
/* 143 to 255 reserved for future growth */
|
|
|
|
ZB_ZCL_METERING_RESERVED = 143
|
|
};
|
|
|
|
|
|
/** @brief @e TemperatureUnitOfMeasure Attribute values
|
|
* @see @ref ZB_ZCL_ATTR_METERING_TEMPERATURE_UNIT_OF_MEASURE_ID
|
|
* @see SE 1.4 spec, subclause 3.2.2.4.13, table D.28
|
|
*/
|
|
enum zb_zcl_metering_temperature_unit_of_measure_e
|
|
{
|
|
ZB_ZCL_METERING_TEMPERATURE_UNIT_KELVIN_BINARY = 0x00, /**< K (Degrees Kelvin) in pure Binary format. */
|
|
ZB_ZCL_METERING_TEMPERATURE_UNIT_CELSIUS_BINARY = 0x01, /**< C (Degrees Celsius) in pure Binary format. */
|
|
ZB_ZCL_METERING_TEMPERATURE_UNIT_FAHRENHEIT_BINARY = 0x02, /**< F (Degrees Fahrenheit) in pure Binary format. */
|
|
/* 0x03 - 0x7F reserved for future use */
|
|
ZB_ZCL_METERING_TEMPERATURE_UNIT_KELVIN_BCD = 0x80, /**< K (Degrees Kelvin) in BCD format. */
|
|
ZB_ZCL_METERING_TEMPERATURE_UNIT_CELSIUS_BCD = 0x81, /**< C (Degrees Celsius) in BCD format. */
|
|
ZB_ZCL_METERING_TEMPERATURE_UNIT_FAHRENHEIT_BCD = 0x82, /**< F (Degrees Fahrenheit) in BCD format. */
|
|
/* 0x83 - 0xFF reserved for future use */
|
|
};
|
|
|
|
/**
|
|
* The generic Alarm Group maps the status from the @e MeterStatus attribute into a corresponding
|
|
* alarm.
|
|
* @see SE spec, Table D-35
|
|
*/
|
|
enum zb_zcl_metering_generic_alarm_group_e
|
|
{
|
|
ZB_ZCL_METERING_ALARM_CHECK_METER = 0x00, /**< Check meter */
|
|
ZB_ZCL_METERING_ALARM_LOW_BATTERY = 0x01, /**< Low battery */
|
|
ZB_ZCL_METERING_ALARM_TAMPER_DETECT = 0x02, /**< Tamper detect */
|
|
ZB_ZCL_METERING_ALARM_ELECTRICITY_POWER_FAILURE = 0x03, /**< Electricity: Power Failure */
|
|
ZB_ZCL_METERING_ALARM_WATER_PIPE_EMPTY = 0x03, /**< Water: Pipe Empty */
|
|
ZB_ZCL_METERING_ALARM_HEAT_TEMPERATURE_SENSOR = 0x03, /**< Heat: Temperature Sensor */
|
|
ZB_ZCL_METERING_ALARM_COOLING_TEMPERATURE_SENSOR = 0x03, /**< Cooling Temperature Sensor */
|
|
ZB_ZCL_METERING_ALARM_ELECTRICITY_POWER_QUALITY = 0x04, /**< Electricity: Power Quality */
|
|
ZB_ZCL_METERING_ALARM_GAS_LOW_PRESSURE = 0x04, /**< Gas: Low Pressure */
|
|
ZB_ZCL_METERING_ALARM_WATER_LOW_PRESSURE = 0x04, /**< Water: Low Pressure */
|
|
ZB_ZCL_METERING_ALARM_HEAT_BURST_DETECT = 0x04, /**< Heat: Burst Detect */
|
|
ZB_ZCL_METERING_ALARM_COOLING_BURST_DETECT = 0x04, /**< Cooling: Burst Detect */
|
|
ZB_ZCL_METERING_ALARM_LEAK_DETECT = 0x05, /**< Leak detect */
|
|
ZB_ZCL_METERING_ALARM_SERVICE_DISCONNECT = 0x06, /**< Service Disconnect */
|
|
ZB_ZCL_METERING_ALARM_ELECTRICITY_RESERVED = 0x07, /**< Electricity: Reserved */
|
|
ZB_ZCL_METERING_ALARM_GAS_REVERSE_FLOW = 0x07, /**< Gas: Reverse Flow */
|
|
ZB_ZCL_METERING_ALARM_WATER_REVERSE_FLOW = 0x07, /**< Water: Reverse Flow */
|
|
ZB_ZCL_METERING_ALARM_HEAT_FLOW_SENSOR = 0x07, /**< Heat: Flow Sensor */
|
|
ZB_ZCL_METERING_ALARM_COOLING_FLOW_SENSOR = 0x07, /**< Cooling: Flow Sensor */
|
|
ZB_ZCL_METERING_ALARM_METER_COVER_REMOVED = 0x08, /**< Meter Cover Removed */
|
|
ZB_ZCL_METERING_ALARM_METER_COVER_CLOSED = 0x09, /**< Meter Cover Closed */
|
|
ZB_ZCL_METERING_ALARM_STRONG_MAGNETIC_FIELD = 0x0A, /**< Strong Magnetic Field */
|
|
ZB_ZCL_METERING_ALARM_NO_STRONG_MAGNETIC_FIELD = 0x0B, /**< No Strong Magnetic Field */
|
|
ZB_ZCL_METERING_ALARM_BATTERY_FAILURE = 0x0C, /**< Battery Failure */
|
|
ZB_ZCL_METERING_ALARM_PROGRAM_MEMORY_ERROR = 0x0D, /**< Program Memory Error */
|
|
ZB_ZCL_METERING_ALARM_RAM_ERROR = 0x0E, /**< Ram Error */
|
|
ZB_ZCL_METERING_ALARM_NV_MEMORY_ERROR = 0x0F /**< NV Memory Error */
|
|
};
|
|
|
|
|
|
/**
|
|
* The Electricity Alarm Group defines alarms specific for electricity meters.
|
|
* @see SE spec, Table D-36
|
|
*/
|
|
enum zb_zcl_metering_electricity_alarm_group_e
|
|
{
|
|
ZB_ZCL_METERING_ALARM_LOW_VOLTAGE_L1 = 0x10, /**< Low Voltage L1 */
|
|
ZB_ZCL_METERING_ALARM_HIGH_VOLTAGE_L1 = 0x11, /**< High Voltage L1 */
|
|
ZB_ZCL_METERING_ALARM_LOW_VOLTAGE_L2 = 0x12, /**< Low Voltage L2 */
|
|
ZB_ZCL_METERING_ALARM_HIGH_VOLTAGE_L2 = 0x13, /**< High Voltage L2 */
|
|
ZB_ZCL_METERING_ALARM_LOW_VOLTAGE_L3 = 0x14, /**< Low Voltage L3 */
|
|
ZB_ZCL_METERING_ALARM_HIGH_VOLTAGE_L3 = 0x15, /**< High Voltage L3 */
|
|
ZB_ZCL_METERING_ALARM_OVER_CURRENT_L1 = 0x16, /**< Over Current L1 */
|
|
ZB_ZCL_METERING_ALARM_OVER_CURRENT_L2 = 0x17, /**< Over Current L2 */
|
|
ZB_ZCL_METERING_ALARM_OVER_CURRENT_L3 = 0x18, /**< Over Current L3 */
|
|
ZB_ZCL_METERING_ALARM_FREQUENCY_TOO_LOW_L1 = 0x19, /**< Frequency too Low L1 */
|
|
ZB_ZCL_METERING_ALARM_FREQUENCY_TOO_HIGH_L1 = 0x1A, /**< Frequency too High L1 */
|
|
ZB_ZCL_METERING_ALARM_FREQUENCY_TOO_LOW_L2 = 0x1B, /**< Frequency too Low L2 */
|
|
ZB_ZCL_METERING_ALARM_FREQUENCY_TOO_HIGH_L2 = 0x1C, /**< Frequency too High L2 */
|
|
ZB_ZCL_METERING_ALARM_FREQUENCY_TOO_LOW_L3 = 0x1D, /**< Frequency too Low L3 */
|
|
ZB_ZCL_METERING_ALARM_FREQUENCY_TOO_HIGH_L3 = 0x1E, /**< Frequency too High L3 */
|
|
ZB_ZCL_METERING_ALARM_GROUND_FAULT = 0x1F, /**< Ground Fault */
|
|
ZB_ZCL_METERING_ALARM_ELECTRIC_TAMPER_DETECT = 0x20, /**< Electric Tamper Detect */
|
|
ZB_ZCL_METERING_ALARM_INCORRECT_POLARITY = 0x21, /**< Incorrect Polarity */
|
|
ZB_ZCL_METERING_ALARM_CURRENT_NO_VOLTAGE = 0x22, /**< Current No Voltage */
|
|
ZB_ZCL_METERING_ALARM_UNDER_VOLTAGE = 0x23, /**< Under Voltage */
|
|
ZB_ZCL_METERING_ALARM_OVER_VOLTAGE = 0x24, /**< Over Voltage */
|
|
ZB_ZCL_METERING_ALARM_NORMAL_VOLTAGE = 0x25, /**< Normal Voltage */
|
|
ZB_ZCL_METERING_ALARM_PF_BELOW_THRESHOLD = 0x26, /**< PF Below Threshold */
|
|
ZB_ZCL_METERING_ALARM_PF_ABOVE_THRESHOLD = 0x27, /**< PF Above Threshold */
|
|
ZB_ZCL_METERING_ALARM_TERMINAL_COVER_REMOVED = 0x28, /**< Terminal Cover Removed */
|
|
ZB_ZCL_METERING_ALARM_TERMINAL_COVER_CLOSED = 0x29, /**< Terminal Cover Closed */
|
|
};
|
|
|
|
|
|
/**
|
|
* The Generic Flow/Pressure Alarm Group defines alarms specific for Flow/Pressure based meters
|
|
* i.e. Water, Heat, Cooling, or Gas meters.
|
|
* @see SE spec, Table D-37
|
|
*/
|
|
enum zb_zcl_metering_generic_flow_pressure_alarm_group_e
|
|
{
|
|
ZB_ZCL_METERING_ALARM_BURST_DETECT = 0x30, /**< Burst detect */
|
|
ZB_ZCL_METERING_ALARM_PRESSURE_TOO_LOW = 0x31, /**< Pressure too low */
|
|
ZB_ZCL_METERING_ALARM_PRESSURE_TOO_HIGH = 0x32, /**< Pressure too high */
|
|
ZB_ZCL_METERING_ALARM_FLOW_SENSOR_COMMUNICATION_ERROR = 0x33, /**< Flow sensor communication error */
|
|
ZB_ZCL_METERING_ALARM_FLOW_SENSOR_MEASUREMENT_FAULT = 0x34, /**< Flow sensor measurement fault */
|
|
ZB_ZCL_METERING_ALARM_FLOW_SENSOR_REVERSE_FLOW = 0x35, /**< Flow sensor reverse flow */
|
|
ZB_ZCL_METERING_ALARM_FLOW_SENSOR_AIR_DETECT = 0x36, /**< Flow sensor air detect */
|
|
ZB_ZCL_METERING_ALARM_PIPE_EMPTY = 0x37, /**< Pipe empty */
|
|
};
|
|
|
|
|
|
/**
|
|
* The Heat and Cooling Specific Alarm Group defines alarms specific for Heat or Cooling meters
|
|
* @see SE spec, Table D-39
|
|
*/
|
|
enum zb_zcl_metering_heat_and_cooling_specific_alarm_group_e
|
|
{
|
|
ZB_ZCL_METERING_ALARM_INLET_TEMPERATURE_SENSOR_FAULT = 0x50, /**< Inlet Temperature Sensor Fault */
|
|
ZB_ZCL_METERING_ALARM_OUTLET_TEMPERATURE_SENSOR_FAULT = 0x51, /**< Outlet Temperature Sensor Fault */
|
|
};
|
|
|
|
|
|
/**
|
|
* The Gas Specific Alarm Group defines alarms specific for Gas meters as defined below.
|
|
* @see SE spec, Table D-40
|
|
*/
|
|
enum zb_zcl_metering_gas_specific_alarm_group_e
|
|
{
|
|
ZB_ZCL_METERING_ALARM_TILT_TAMPER = 0x60, /**< Tilt Tamper */
|
|
ZB_ZCL_METERING_ALARM_BATTERY_COVER_REMOVED = 0x61, /**< Battery Cover Removed */
|
|
ZB_ZCL_METERING_ALARM_BATTERY_COVER_CLOSED = 0x62, /**< Battery Cover Closed */
|
|
ZB_ZCL_METERING_ALARM_EXCESS_FLOW = 0x63, /**< Excess Flow */
|
|
ZB_ZCL_METERING_ALARM_TILT_TAMPER_ENDED = 0x64, /**< Tilt Tamper Ended */
|
|
};
|
|
|
|
|
|
/**
|
|
* The Extended Generic Alarm Group is an additional set of generic meter alarms.
|
|
* @see SE spec, Table D-41
|
|
*/
|
|
enum zb_zcl_metering_extended_generic_alarm_group_e
|
|
{
|
|
ZB_ZCM_METERING_ALARM_MEASUREMENT_SYSTEM_ERROR = 0x70, /**< Measurement System Error */
|
|
ZB_ZCM_METERING_ALARM_WATCHDOG_ERROR = 0x71, /**< Watchdog Error */
|
|
ZB_ZCM_METERING_ALARM_SUPPLY_DISCONNECT_FAILURE = 0x72, /**< Supply Disconnect Failure */
|
|
ZB_ZCM_METERING_ALARM_SUPPLY_CONNECT_FAILURE = 0x73, /**< Supply Connect Failure */
|
|
ZB_ZCM_METERING_ALARM_MEASUREMENT_SOFTWARE_CHANGED = 0x74, /**< Measurement Software Changed */
|
|
ZB_ZCM_METERING_ALARM_DST_ENABLED = 0x75, /**< DST enabled */
|
|
ZB_ZCM_METERING_ALARM_DST_DISABLED = 0x76, /**< DST disabled */
|
|
ZB_ZCM_METERING_ALARM_CLOCK_ADJ_BACKWARD = 0x77, /**< Clock Adj Backward (the internal clock
|
|
has applied a negative adjustment) */
|
|
ZB_ZCM_METERING_ALARM_CLOCK_ADJ_FORWARD = 0x78, /**< Clock Adj Forward (the internal clock
|
|
has applied a positive adjustment) */
|
|
ZB_ZCM_METERING_ALARM_CLOCK_INVALID = 0x79, /**< Clock Invalid */
|
|
ZB_ZCM_METERING_ALARM_COMMUNICATION_ERROR_HAN = 0x7A, /**< Communication Error HAN */
|
|
ZB_ZCM_METERING_ALARM_COMMUNICATION_OK_HAN = 0x7B, /**< Communication OK HAN */
|
|
ZB_ZCM_METERING_ALARM_METER_FRAUD_ATTEMPT = 0x7C, /**< Meter Fraud Attempt */
|
|
ZB_ZCM_METERING_ALARM_POWER_LOSS = 0x7D, /**< Power Loss */
|
|
ZB_ZCM_METERING_ALARM_UNUSUAL_HAN_TRAFFIC = 0x7E, /**< Unusual HAN Traffic */
|
|
ZB_ZCM_METERING_ALARM_UNEXPECTED_CLOCK_CHANGE = 0x7F, /**< Unexpected Clock Change */
|
|
ZB_ZCM_METERING_ALARM_COMMS_USING_UNAUTHENTICATED_COMPONENT = 0x80, /**< Comms Using Unauthenticated Component */
|
|
ZB_ZCM_METERING_ALARM_ERROR_REG_CLEAR = 0x81, /**< Error Reg Clear */
|
|
ZB_ZCM_METERING_ALARM_ALARM_REG_CLEAR = 0x82, /**< Alarm Reg Clear */
|
|
ZB_ZCM_METERING_ALARM_UNEXPECTED_HW_RESET = 0x83, /**< Unexpected HW Reset */
|
|
ZB_ZCM_METERING_ALARM_UNEXPECTED_PROGRAM_EXECUTION = 0x84, /**< Unexpected Program Execution */
|
|
ZB_ZCM_METERING_ALARM_EVENTLOG_CLEARED = 0x85, /**< EventLog Cleared */
|
|
ZB_ZCM_METERING_ALARM_LIMIT_THRESHOLD_EXCEEDED = 0x86, /**< Limit Threshold Exceeded */
|
|
ZB_ZCM_METERING_ALARM_LIMIT_THRESHOLD_OK = 0x87, /**< Limit Threshold OK */
|
|
ZB_ZCM_METERING_ALARM_LIMIT_THRESHOLD_CHANGED = 0x88, /**< Limit Threshold Changed */
|
|
ZB_ZCM_METERING_ALARM_MAXIMUM_DEMAND_EXCEEDED = 0x89, /**< Maximum Demand Exceeded */
|
|
ZB_ZCM_METERING_ALARM_PROFILE_CLEARED = 0x8A, /**< Profile Cleared */
|
|
ZB_ZCM_METERING_ALARM_SAMPLING_BUFFER_CLEARED = 0x8B, /**< Sampling Buffer cleared */
|
|
ZB_ZCM_METERING_ALARM_BATTERY_WARNING = 0x8C, /**< Battery Warning */
|
|
ZB_ZCM_METERING_ALARM_WRONG_SIGNATURE = 0x8D, /**< Wrong Signature */
|
|
ZB_ZCM_METERING_ALARM_NO_SIGNATURE = 0x8E, /**< No Signature */
|
|
ZB_ZCM_METERING_ALARM_UNAUTHORISED_ACTION_FROM_HAN = 0x8F, /**< Unauthorised Action from HAN */
|
|
ZB_ZCM_METERING_ALARM_FAST_POLLING_START = 0x90, /**< Fast Polling Start */
|
|
ZB_ZCM_METERING_ALARM_FAST_POLLING_END = 0x91, /**< Fast Polling End */
|
|
ZB_ZCM_METERING_ALARM_METER_REPORTING_INTERVAL_CHANGED = 0x92, /**< Meter Reporting Interval Changed */
|
|
ZB_ZCM_METERING_ALARM_DISCONNECT_DUE_TO_LOAD_LIMIT = 0x93, /**< Disconnect Due to Load Limit */
|
|
ZB_ZCM_METERING_ALARM_METER_SUPPLY_STATUS_REGISTER_CHANGED = 0x94, /**< Meter Supply Status Register Changed */
|
|
ZB_ZCM_METERING_ALARM_METER_ALARM_STATUS_REGISTER_CHANGED = 0x95, /**< Meter Alarm Status Register Changed */
|
|
ZB_ZCM_METERING_ALARM_EXTENDED_METER_ALARM_STATUS_REGISTER_CHANGED = 0x96, /**< Extended Meter Alarm Status Register Changed. */
|
|
};
|
|
|
|
|
|
/**
|
|
* The Manufacturer Specific Alarm Group defines alarms specific for any meters. These are used
|
|
* for meter specific functionality that is not covered by the current smart energy specification.
|
|
* @see SE spec, Table D-42
|
|
*/
|
|
enum zb_zcl_metering_manufacturer_specific_alarm_group_e
|
|
{
|
|
ZB_ZCL_METERING_ALARM_MANUFACTURER_SPECIFIC_A = 0xB0, /**< Manufacturer Specific A */
|
|
ZB_ZCL_METERING_ALARM_MANUFACTURER_SPECIFIC_B = 0xB1, /**< Manufacturer Specific B */
|
|
ZB_ZCL_METERING_ALARM_MANUFACTURER_SPECIFIC_C = 0xB2, /**< Manufacturer Specific C */
|
|
ZB_ZCL_METERING_ALARM_MANUFACTURER_SPECIFIC_D = 0xB3, /**< Manufacturer Specific D */
|
|
ZB_ZCL_METERING_ALARM_MANUFACTURER_SPECIFIC_E = 0xB4, /**< Manufacturer Specific E */
|
|
ZB_ZCL_METERING_ALARM_MANUFACTURER_SPECIFIC_F = 0xB5, /**< Manufacturer Specific F */
|
|
ZB_ZCL_METERING_ALARM_MANUFACTURER_SPECIFIC_G = 0xB6, /**< Manufacturer Specific G */
|
|
ZB_ZCL_METERING_ALARM_MANUFACTURER_SPECIFIC_H = 0xB7, /**< Manufacturer Specific H */
|
|
ZB_ZCL_METERING_ALARM_MANUFACTURER_SPECIFIC_I = 0xB8, /**< Manufacturer Specific I */
|
|
};
|
|
|
|
|
|
/** Service Disconnect Reasons
|
|
* @see Linky Metering Cluster spec, Table D-16
|
|
*/
|
|
enum zb_zcl_metering_service_disconnect_reasons_e
|
|
{
|
|
ZB_ZCL_METERING_REASON_ON = 0x00, /**< ON (Service NOT disconnected) */
|
|
ZB_ZCL_METERING_REASON_OFF_DUE_TO_OVER_POWER = 0x01, /**< OFF due to over power */
|
|
ZB_ZCL_METERING_REASON_OFF_DUE_TO_OVER_VOLTAGE = 0x02, /**< OFF due to over voltage */
|
|
ZB_ZCL_METERING_REASON_OFF_DUE_TO_REMOTE_DNO_LOAD_CONTROL = 0x03, /**< OFF due to Remote DNO Load Control */
|
|
ZB_ZCL_METERING_REASON_OFF_BY_OTHER_REMOTE_COMMAND = 0x04, /**< OFF by other remote command */
|
|
ZB_ZCL_METERING_REASON_OFF_DUE_TO_OVERHEATING_SHORT_CIRCUIT = 0x05, /**< OFF due to overheating,
|
|
I > In (Maximum Current) - short circuit */
|
|
ZB_ZCL_METERING_REASON_OFF_DUE_TO_OVERHEATING_OTHER = 0x06, /**< OFF due to overheating,
|
|
I < In (Maximum Current) - other */
|
|
};
|
|
|
|
/** @brief Default value for Metering cluster revision global attribute */
|
|
#define ZB_ZCL_METERING_CLUSTER_REVISION_DEFAULT ((zb_uint16_t)0x0002u)
|
|
|
|
/*! @brief If set, suppress leading zeros */
|
|
#define ZB_ZCL_METERING_FORMATTING_SUPPRESS_ZERO(b) (((b) & 0x80)==0x80)
|
|
|
|
/*! @brief Number of Digits to the right of the Decimal Point */
|
|
#define ZB_ZCL_METERING_FORMATTING_LEFT(b) (((b)>>3) & 0x07)
|
|
|
|
/*! @brief Number of Digits to the left of the Decimal Point */
|
|
#define ZB_ZCL_METERING_FORMATTING_RIGHT(b) ((b) & 0x07)
|
|
|
|
/*! @brief Set summation formatting */
|
|
#define ZB_ZCL_METERING_FORMATTING_SET(suppress_zero, left, right) \
|
|
( ((suppress_zero) ? 0x80 : 0) | (((left) & 7)<<3) | ((right) & 7) )
|
|
|
|
/** @brief Default value for Status attribute */
|
|
#define ZB_ZCL_METERING_STATUS_DEFAULT_VALUE 0x00
|
|
|
|
/** @brief Default value for Status attribute */
|
|
#define ZB_ZCL_METERING_UNIT_OF_MEASURE_DEFAULT_VALUE 0x00
|
|
|
|
/** @brief Default value for Instantaneous Demand attribute */
|
|
#define ZB_ZCL_METERING_INSTANTANEOUS_DEMAND_DEFAULT_VALUE ZB_INIT_UINT24(0x00, 0x0000)
|
|
|
|
/** @brief Default value for DailyFreezeTime attribute */
|
|
#define ZB_ZCL_METERING_DAILY_FREEZE_TIME_DEFAULT_VALUE ((zb_uint16_t)0x0000)
|
|
|
|
/** @brief Default value for PowerFactor attribute */
|
|
#define ZB_ZCL_METERING_POWER_FACTOR_DEFAULT_VALUE ((zb_int8_t)0x00)
|
|
|
|
/** @brief Default value for DefaultUpdatePeriod attribute */
|
|
#define ZB_ZCL_METERING_DEFAULT_UPDATE_PERIOD_DEFAULT_VALUE ((zb_uint8_t)0x1E)
|
|
|
|
/** @brief Default value for FastPollUpdatePeriod attribute */
|
|
#define ZB_ZCL_METERING_FAST_POLL_UPDATE_PERIOD_DEFAULT_VALUE ((zb_uint8_t)0x05)
|
|
|
|
/** @brief Default value for PresetReadingTime attribute */
|
|
#define ZB_ZCL_METERING_PRESET_READING_TIME_DEFAULT_VALUE ((zb_uint16_t)0x0000)
|
|
|
|
/** @brief Default value for MaxNumberOfPeriodsDelivered attribute */
|
|
#define ZB_ZCL_METERING_MAX_NUMBER_OF_PERIODS_DELIVERED_DEFAULT_VALUE ((zb_uint8_t)0x18)
|
|
|
|
/** @brief Default value for GenericAlarmMask attribute */
|
|
#define ZB_ZCL_METERING_GENERIC_ALARM_MASK_DEFAULT_VALUE ((zb_uint16_t)0xFFFF)
|
|
|
|
/** @brief Default value for ElectricityAlarmMask attribute */
|
|
#define ZB_ZCL_METERING_ELECTRICITY_ALARM_MASK_DEFAULT_VALUE ((zb_uint32_t)0xFFFFFFFF)
|
|
|
|
/** @brief Default value for GenericFlowPressureAlarmMask attribute */
|
|
#define ZB_ZCL_METERING_GENERIC_FLOW_PRESSURE_ALARM_MASK_DEFAULT_VALUE ((zb_uint16_t)0xFFFF)
|
|
|
|
/** @brief Default value for WaterSpecificAlarmMask attribute */
|
|
#define ZB_ZCL_METERING_WATER_SPECIFIC_ALARM_MASK_DEFAULT_VALUE ((zb_uint16_t)0xFFFF)
|
|
|
|
/** @brief Default value for HeatAndCoolingSpecificAlarmMask attribute */
|
|
#define ZB_ZCL_METERING_HEAT_AND_COOLING_SPECIFIC_ALARM_MASK_DEFAULT_VALUE ((zb_uint16_t)0xFFFF)
|
|
|
|
/** @brief Default value for GasSpecificAlarmMask attribute */
|
|
#define ZB_ZCL_METERING_GAS_SPECIFIC_ALARM_MASK_DEFAULT_VALUE ((zb_uint16_t)0xFFFF)
|
|
|
|
/** @brief Default value for FastPollUpdatePeriod attribute */
|
|
#define ZB_ZCL_METERING_LINKY_MODE_ON_OPERATION_DEFAULT_VALUE ((zb_uint8_t)0x00)
|
|
/** @} */ /* ZB_ZCL_METERING_SRV_ATTRS */
|
|
|
|
|
|
/** @defgroup ZB_ZCL_METERING_CMDS Metering cluster commands
|
|
* @{
|
|
*/
|
|
|
|
|
|
/** Metering cluster client command identifiers.
|
|
* @see SE spec, subclause D.3.3.3.1
|
|
*/
|
|
typedef enum zb_zcl_metering_cli_cmd_e
|
|
{
|
|
|
|
/* (O) */
|
|
ZB_ZCL_METERING_CLI_CMD_GET_PROFILE = 0x00, /**< @e GetProfile command */
|
|
/* (O) */
|
|
ZB_ZCL_METERING_CLI_CMD_REQUEST_MIRROR_RESPONSE, /**< The @e RequestMirrorResponse
|
|
* command allows the ESI to inform a
|
|
* sleepy Metering Device it has the
|
|
* ability to store and mirror its data.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_CLI_CMD_MIRROR_REMOVED, /**<The @e MirrorRemovedCommand allows
|
|
* the ESI to inform a sleepy Metering
|
|
* Device mirroring support has been
|
|
* removed or halted.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_CLI_CMD_REQUEST_FAST_POLL_MODE, /**< @e RequestFastPollMode command */
|
|
/* (O) */
|
|
ZB_ZCL_METERING_CLI_CMD_SCHEDULE_SNAPSHOT, /**< This command is used to set up a
|
|
* schedule of when the device shall
|
|
* create snapshot data.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_CLI_CMD_TAKE_SNAPSHOT, /**< This command is used to instruct the
|
|
* cluster server to take a single snapshot.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_CLI_CMD_GET_SNAPSHOT, /**< This command is used to request
|
|
* snapshot data from the cluster server. */
|
|
/* (O) */
|
|
ZB_ZCL_METERING_CLI_CMD_START_SAMPLING, /**< The sampling mechanism allows a set of
|
|
* samples of the specified type of data to be taken,
|
|
* commencing at the stipulated start time.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_CLI_CMD_GET_SAMPLED_DATA, /**< This command is used to request sampled
|
|
* data from the server.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_CLI_CMD_MIRROR_REPORT_ATTRIBUTE_RESPONSE, /**< This command is sent in response to the
|
|
* @e ReportAttribute command when the
|
|
* @e MirrorReporting attribute is set.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_CLI_CMD_RESET_LOAD_LIMIT_COUNTER, /**< The ResetLoadLimitCounter command shall
|
|
* cause the LoadLimitCounter attribute
|
|
* to be reset
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_CLI_CMD_CHANGE_SUPPLY, /**< This command is sent from the Head-end or
|
|
* ESI to the Metering Device to instruct it
|
|
* to change the status of the valve or load
|
|
* switch, i.e. the supply.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_CLI_CMD_LOCAL_CHANGE_SUPPLY, /**< This command is a simplified version of the
|
|
* Change Supply command, intended to be sent
|
|
* from an IHD to a meter as the consequence
|
|
* of a user action on the IHD.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_CLI_CMD_SET_SUPPLY_STATUS, /**< This command is used to specify the required
|
|
* status of the supply following the occurrence
|
|
* of certain events on the meter.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_CLI_CMD_SET_UNCONTROLLED_FLOW_THRESHOLD, /**< This command is used to update the 'Uncontrolled Flow Rate'
|
|
* configuration data used by flow meters.
|
|
*/
|
|
} zb_zcl_metering_cli_cmd_t;
|
|
|
|
|
|
/** Metering cluster server command identifiers.
|
|
* @see SE spec, D.3.2.3.1
|
|
*/
|
|
typedef enum zb_zcl_metering_srv_cmd_e
|
|
{
|
|
/* (O) */
|
|
ZB_ZCL_METERING_SRV_CMD_GET_PROFILE_RESPONSE = 0x00, /**< Get Profile Response */
|
|
/* (O) */
|
|
ZB_ZCL_METERING_SRV_CMD_REQUEST_MIRROR, /**< This command is used to request the
|
|
* ESI to mirror Metering Device data.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_SRV_CMD_REMOVE_MIRROR, /**< This command is used to request the ESI
|
|
* to remove its mirror of Metering Device data.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_SRV_CMD_REQUEST_FAST_POLL_MODE_RESPONSE, /**< @e RequestFastPollModeResponse command*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_SRV_CMD_SCHEDULE_SNAPSHOT_RESPONSE, /**< This command is generated in response to a
|
|
* ScheduleSnapshot command, and is sent to confirm
|
|
* whether the requested snapshot schedule has been set up.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_SRV_CMD_TAKE_SNAPSHOT_RESPONSE, /**< This command is generated in response to a TakeSnapshot
|
|
* command, and is sent to confirm whether the requested
|
|
* snapshot has been accepted and successfully taken.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_SRV_CMD_PUBLISH_SNAPSHOT, /**< This command is generated in response
|
|
* to a GetSnapshot command or when a new
|
|
* snapshot is created. */
|
|
/* (O) */
|
|
ZB_ZCL_METERING_SRV_CMD_GET_SAMPLED_DATA_RESPONSE, /**< This command is used to send the requested
|
|
* sample data to the client. It is generated in response
|
|
* to a @e GetSampledData command
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_SRV_CMD_CONFIGURE_MIRROR, /**<Where 'Two Way Mirroring' is being implemented,
|
|
* this command shall be sent to the mirror once the
|
|
* mirror has been created. The command allows a BOMD
|
|
* to provide the operational configuration of the
|
|
* associated Mirror.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_SRV_CMD_CONFIGURE_NOTIFICATION_SCHEME, /**< Where 'Two Way Mirroring' is being implemented,
|
|
* and a non-default Notification Scheme is to be used,
|
|
* this command shall be sent to the mirror once the
|
|
* mirror has been created.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_SRV_CMD_CONFIGURE_NOTIFICATION_FLAG, /**< Where 'Two Way Mirroring' is being implemented,
|
|
* and a non-default Notification Scheme is to
|
|
* be used, the @e ConfigureNotificationFlags command
|
|
* allows a BOMD to set the commands relating to the
|
|
* bit value for each NotificationFlags#N attribute
|
|
* that the scheme is proposing to use.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_SRV_CMD_GET_NOTIFIED_MESSAGE, /**< The GetNotifiedMessage command is used only when a
|
|
* BOMD is being mirrored. This command provides a method
|
|
* for the BOMD to notify the Mirror message queue that
|
|
* it wants to receive commands that the Mirror has queued.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_SRV_CMD_SUPPLY_STATUS_RESPONSE, /**< This command is transmitted by a Metering Device in response
|
|
* to a Change Supply command.
|
|
*/
|
|
/* (O) */
|
|
ZB_ZCL_METERING_SRV_CMD_START_SAMPLING_RESPONSE, /**< This command is transmitted by a Metering Device in response
|
|
* to a StartSampling command.
|
|
*/
|
|
} zb_zcl_metering_srv_cmd_t;
|
|
|
|
/* METERING cluster commands list : only for information - do not modify */
|
|
#define ZB_ZCL_CLUSTER_ID_METERING_SERVER_ROLE_GENERATED_CMD_LIST \
|
|
ZB_ZCL_METERING_SRV_CMD_GET_PROFILE_RESPONSE, \
|
|
ZB_ZCL_METERING_SRV_CMD_REQUEST_FAST_POLL_MODE_RESPONSE, \
|
|
ZB_ZCL_METERING_SRV_CMD_PUBLISH_SNAPSHOT, \
|
|
ZB_ZCL_METERING_SRV_CMD_GET_SAMPLED_DATA_RESPONSE
|
|
|
|
#define ZB_ZCL_CLUSTER_ID_METERING_CLIENT_ROLE_RECEIVED_CMD_LIST ZB_ZCL_CLUSTER_ID_METERING_SERVER_ROLE_GENERATED_CMD_LIST
|
|
|
|
#define ZB_ZCL_CLUSTER_ID_METERING_CLIENT_ROLE_GENERATED_CMD_LIST \
|
|
ZB_ZCL_METERING_CLI_CMD_GET_PROFILE, \
|
|
ZB_ZCL_METERING_CLI_CMD_REQUEST_FAST_POLL_MODE, \
|
|
ZB_ZCL_METERING_CLI_CMD_GET_SNAPSHOT, \
|
|
ZB_ZCL_METERING_CLI_CMD_GET_SAMPLED_DATA
|
|
|
|
#define ZB_ZCL_CLUSTER_ID_METERING_SERVER_ROLE_RECEIVED_CMD_LIST ZB_ZCL_CLUSTER_ID_METERING_CLIENT_ROLE_GENERATED_CMD_LIST
|
|
|
|
/** Interval Channel Values
|
|
* @see SE spec, subclause D.3.3.3.1.1.1
|
|
*/
|
|
enum zb_zcl_metering_interval_channel_e
|
|
{
|
|
ZB_ZCL_METERING_CONSUMPTION_DELIVERED = 0,
|
|
ZB_ZCL_METERING_CONSUMPTION_RECEIVED = 1,
|
|
ZB_ZCL_METERING_REACTIVE_CONSUMPTION_DELIVERED = 2,
|
|
ZB_ZCL_METERING_REACTIVE_CONSUMPTION_RECEIVED = 3,
|
|
/* Value 4 is reserved. Values 5 - 255 is unused */
|
|
};
|
|
|
|
|
|
/** @ref ZB_ZCL_METERING_CLI_CMD_GET_PROFILE "GetProfile" command payload
|
|
* @see SE spec, subclause D.3.3.3.1.1.1
|
|
*/
|
|
typedef ZB_PACKED_PRE struct zb_zcl_metering_get_profile_payload_s
|
|
{
|
|
/** Enumerated value used to select the quantity of interest returned by the
|
|
* @e GetProfileResponse command.
|
|
* @see @ref zb_zcl_metering_interval_channel_e
|
|
*/
|
|
zb_uint8_t interval_channel;
|
|
/** It is a 32-bit value (in UTCTime) used to select an Intervals block
|
|
* from all the Intervals blocks available.
|
|
*/
|
|
zb_uint32_t end_time;
|
|
/** Represents the number of intervals being requested. */
|
|
zb_uint8_t number_of_periods;
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_get_profile_payload_t;
|
|
|
|
|
|
/** Status Field Values
|
|
* @see SE spec, Table D-48
|
|
*/
|
|
/* FIXME: Discuss prefix */
|
|
enum zb_zcl_metering_status_field_e
|
|
{
|
|
ZB_ZCL_METERING_SUCCESS = 0x00, /**< Success */
|
|
ZB_ZCL_METERING_UNDEFINED_INTERVAL_CHANNEL_REQUESTED = 0x01, /**< Undefined Interval Channel requested */
|
|
ZB_ZCL_METERING_INTERVAL_CHANNEL_NOT_SUPPORTED = 0x02, /**< Interval Channel not supported */
|
|
ZB_ZCL_METERING_INVALID_END_TIME = 0x03, /**< Invalid End Time */
|
|
ZB_ZCL_METERING_MORE_PERIODS_REQUESTED_THAN_CAN_BE_RETURNED = 0x04, /**< More periods requested than can be returned */
|
|
ZB_ZCL_METERING_NO_INTERVALS_AVAILABLE_FOR_THE_REQUESTED_TIME = 0x05 /**< No intervals available for the requested time */
|
|
};
|
|
|
|
|
|
/** Profile Interval Period
|
|
* @see SE spec, Table D-49
|
|
*/
|
|
enum zb_zcl_metering_profile_interval_period_e
|
|
{
|
|
ZB_ZCl_METERING_INTERVAL_PERIOD_DAILY = 0, /**< Daily */
|
|
ZB_ZCl_METERING_INTERVAL_PERIOD_60_MINUTES = 1, /**< 60 minutes */
|
|
ZB_ZCl_METERING_INTERVAL_PERIOD_30_MINUTES = 2, /**< 30 minutes */
|
|
ZB_ZCl_METERING_INTERVAL_PERIOD_15_MINUTES = 3, /**< 15 minutes */
|
|
ZB_ZCl_METERING_INTERVAL_PERIOD_10_MINUTES = 4, /**< 10 minutes */
|
|
ZB_ZCl_METERING_INTERVAL_PERIOD_7_5_MINUTES = 5, /**< 7.5 minutes */
|
|
ZB_ZCl_METERING_INTERVAL_PERIOD_5_MINUTES = 6, /**< 5 minutes */
|
|
ZB_ZCl_METERING_INTERVAL_PERIOD_2_5_MINUTES = 7, /**< 2.5 minutes */
|
|
ZB_ZCl_METERING_INTERVAL_PERIOD_1_MINUTE = 8 /**< 1 minute */
|
|
};
|
|
|
|
#define ZB_ZCL_METERING_GET_PROFILE_PAYLOAD_SIZE_IS_VALID(current_size) \
|
|
((current_size >= sizeof(zb_zcl_metering_get_profile_payload_t) ? ZB_TRUE : ZB_FALSE))
|
|
|
|
/** @ref ZB_ZCL_METERING_SRV_CMD_GET_PROFILE_RESPONSE "GetProfileResponse" command payload
|
|
* @see SE spec, subclause D.3.2.3.1.1.1
|
|
*/
|
|
typedef ZB_PACKED_PRE struct zb_zcl_metering_get_profile_response_payload_s
|
|
{
|
|
/** It is 32-bit value (in UTC) representing the end time of the most
|
|
* chronologically recent interval being requested.
|
|
*/
|
|
zb_uint32_t end_time;
|
|
/** Status
|
|
* @see zb_zcl_metering_status_field_e
|
|
*/
|
|
zb_uint8_t status;
|
|
/** Represents the interval or time frame used to capture metered Energy, Gas,
|
|
* and Water consumption for profiling purposes.
|
|
* @see zb_zcl_metering_profile_interval_period_e
|
|
*/
|
|
zb_uint8_t profile_interval_period;
|
|
/** Represents the number of intervals the device is returning.
|
|
*/
|
|
zb_uint8_t number_of_periods_delivered;
|
|
/** Series of interval data captured using the period specified by the
|
|
* @e ProfileIntervalPeriod field. The content of the interval data depends of
|
|
* the type of information requested using the @e Channel field in the
|
|
* @ref ZB_ZCL_METERING_CLI_CMD_GET_PROFILE "GetProfileCommand", and will
|
|
* represent the change in that information since the previous interval.
|
|
*/
|
|
zb_uint24_t *intervals;
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_get_profile_response_payload_t;
|
|
|
|
|
|
/** @ref ZB_ZCL_METERING_CLI_CMD_REQUEST_FAST_POLL_MODE "RequestFastPollMode" command payload
|
|
* @see SE spec, subclause D.3.3.3.1.4
|
|
*/
|
|
typedef ZB_PACKED_PRE struct zb_zcl_metering_request_fast_poll_mode_payload_s
|
|
{
|
|
/** Desired FastPollUpdatePeriod attribute.
|
|
*/
|
|
zb_uint8_t fast_poll_update_period; /* (M) */
|
|
/** Desired duration for the server to remain in fast poll mode not to exceed 15 minutes
|
|
*/
|
|
zb_uint8_t duration_in_minutes; /* (M) */
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_request_fast_poll_mode_payload_t;
|
|
|
|
|
|
/** @ref ZB_ZCL_METERING_SRV_CMD_REQUEST_FAST_POLL_MODE_RESPONSE "RequestFastPollModeResponse" command payload
|
|
* @see SE spec, subclause D.3.3.3.1.4
|
|
*/
|
|
typedef ZB_PACKED_PRE struct zb_zcl_metering_request_fast_poll_mode_response_payload_s
|
|
{
|
|
/** The period at which metering data shall be updated. This may be different than the requested fast poll.
|
|
*/
|
|
zb_uint8_t applied_update_period_in_seconds; /* (M) */
|
|
/** UTC time that indicates when the metering server will terminate fast poll mode and resume
|
|
* updating at the rate specified by @e DefaultUpdatePeriod.
|
|
*/
|
|
zb_uint32_t fast_poll_mode_end_time; /* (M) */
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_request_fast_poll_mode_response_payload_t;
|
|
|
|
|
|
/** @ref ZB_ZCL_METERING_SRV_CMD_GET_SAMPLED_DATA_RESPONSE "GetSampledDataResponse" command payload
|
|
* @see SE spec, subclause D.3.2.3.1.8
|
|
*/
|
|
typedef ZB_PACKED_PRE struct zb_zcl_metering_get_sampled_data_response_payload_s
|
|
{
|
|
/** Unique identifier allocated to this Sampling session. This field allows devices to match
|
|
* response data with the appropriate request.
|
|
*/
|
|
zb_uint16_t sample_id; /* (M) */
|
|
/** A UTC Time field to denote the time of the first sample returned in this response. */
|
|
zb_uint32_t sample_start_time; /* (M) */
|
|
/** An 8-bit enumeration that identifies the type of data being sampled. */
|
|
zb_uint8_t sample_type; /* (M) */
|
|
/** An unsigned 16-bit field representing the interval or time in seconds between samples. */
|
|
zb_uint16_t sample_request_interval; /* (M) */
|
|
/** Represents the number of samples being requested, This value cannot exceed the size stipulated
|
|
* in the @e MaxNumberOfSamples field in the @e StartSampling command.
|
|
*/
|
|
zb_uint16_t number_of_samples; /* (M) */
|
|
/** Series of data samples captured using the interval specified by the @e SampleRequestInterval
|
|
* field in the @e StartSampling command.
|
|
*/
|
|
zb_uint24_t *samples; /* (M) */
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_get_sampled_data_response_payload_t;
|
|
|
|
|
|
/** Sample Type Enumerations
|
|
* @see SE spec, Table D-54
|
|
*/
|
|
enum zb_zcl_metering_sample_type_e
|
|
{
|
|
ZB_ZCL_METERING_SAMPLE_TYPE_CONSUMPTION_DELIVERED = 0, /**< Consumption Delivered */
|
|
ZB_ZCL_METERING_SAMPLE_TYPE_CONSUMPTION_RECEIVED = 1, /**< Consumption Received */
|
|
ZB_ZCL_METERING_SAMPLE_TYPE_REACTIVE_CONSUMPTION_DELIVERED = 2, /**< Reactive Consumption Delivered */
|
|
ZB_ZCL_METERING_SAMPLE_TYPE_REACTIVE_CONSUMPTION_RECEIVED = 3, /**< Reactive Consumption Received */
|
|
ZB_ZCL_METERING_SAMPLE_TYPE_INSTANTANEOUS_DEMAND = 4 /**< InstantaneousDemand*/
|
|
};
|
|
|
|
|
|
/** @ref ZB_ZCL_METERING_CLI_CMD_GET_SAMPLED_DATA "GetSampledData" command payload
|
|
* @see SE spec, subclause D.3.2.3.1.8
|
|
*/
|
|
typedef ZB_PACKED_PRE struct zb_zcl_metering_get_sampled_data_payload_s
|
|
{
|
|
/** Unique identifier allocated to this Sampling session. This field allows devices to match
|
|
* response data with the appropriate request.
|
|
*/
|
|
zb_uint16_t sample_id; /* (M) */
|
|
/** A UTC Timestamp indicating the earliest time of a sample to be returned. */
|
|
zb_uint32_t earliest_sample_time; /* (M) */
|
|
/** An 8-bit enumeration that identifies the type of data being sampled. */
|
|
zb_uint8_t sample_type; /* (M) */
|
|
/** Represents the number of samples being requested, This value cannot exceed the size stipulated
|
|
* in the @e MaxNumberOfSamples field in the @e StartSampling command.
|
|
*/
|
|
zb_uint16_t number_of_samples; /* (M) */
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_get_sampled_data_payload_t;
|
|
|
|
|
|
/** @ref ZB_ZCL_METERING_CLI_CMD_GET_SNAPSHOT "GetSnapshot" command payload
|
|
* @see SE spec, subclause D.3.3.3.1.7
|
|
*/
|
|
typedef ZB_PACKED_PRE struct zb_zcl_metering_get_snapshot_payload_s
|
|
{
|
|
/** A UTC Timestamp indicating the earliest time of a snapshot to be returned by a corresponding
|
|
* Publish Snapshot command.
|
|
*/
|
|
zb_uint32_t earliest_start_time; /* (M) */
|
|
/** A UTC Timestamp indicating the latest time of a snapshot to be returned by a corresponding
|
|
* Publish Snapshot command.
|
|
*/
|
|
zb_uint32_t latest_end_time; /* (M) */
|
|
/** Where multiple snapshots satisfy the selection criteria specified by the other fields in this
|
|
* command, this field identifies the individual snapshot to be returned.
|
|
*/
|
|
zb_uint8_t snapshot_offset; /* (M) */
|
|
/** This field is used to select only snapshots that were taken due to a specific cause. */
|
|
zb_uint32_t snapshot_cause; /* (M) */
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_get_snapshot_payload_t;
|
|
|
|
|
|
/** Snapshot Cause BitMap
|
|
* @see SE spec, Table D-52
|
|
*/
|
|
enum zb_zcl_metering_snapshot_cause_e
|
|
{
|
|
ZB_ZCL_METERING_CAUSE_GENERAL = 1 << 0, /**< General */
|
|
ZB_ZCL_METERING_CAUSE_END_OF_BILLING_PERIOD = 1 << 1, /**< End of Billing Period */
|
|
ZB_ZCL_METERING_CAUSE_END_OF_BLOCK_PERIOD = 1 << 2, /**< End of Block Period */
|
|
ZB_ZCL_METERING_CAUSE_CHANGE_OF_TARIFF_INFORMATION = 1 << 3, /**< Change of Tariff Information */
|
|
ZB_ZCL_METERING_CAUSE_CHANGE_OF_PRICE_MATRIX = 1 << 4, /**< Change of Price Matrix */
|
|
ZB_ZCL_METERING_CAUSE_CHANGE_OF_BLOCK_THRESHOLDS = 1 << 5, /**< Change of Block Thresholds */
|
|
ZB_ZCL_METERING_CAUSE_CHANGE_OF_CV = 1 << 6, /**< Change of CV */
|
|
ZB_ZCL_METERING_CAUSE_CHANGE_OF_CF = 1 << 7, /**< Change of CF */
|
|
ZB_ZCL_METERING_CAUSE_CHANGE_OF_CALENDAR = 1 << 8, /**< Change of Calendar */
|
|
ZB_ZCL_METERING_CAUSE_CRITICAL_PEAK_PRICING = 1 << 9, /**< Critical Peak Pricing */
|
|
ZB_ZCL_METERING_CAUSE_MANUALLY_TRIGGERED_FROM_CLIENT = 1 << 10, /**< Manually Triggered from Client */
|
|
ZB_ZCL_METERING_CAUSE_END_OF_RESOLVE_PERIOD = 1 << 11, /**< End of Resolve Period */
|
|
ZB_ZCL_METERING_CAUSE_CHANGE_OF_TENANCY = 1 << 12, /**< Change of Tenancy */
|
|
ZB_ZCL_METERING_CAUSE_CHANGE_OF_SUPPLIER = 1 << 13, /**< Change of Supplier */
|
|
ZB_ZCL_METERING_CAUSE_CHANGE_OF_METER_MODE = 1 << 14, /**< Change of (Meter) Mode */
|
|
ZB_ZCL_METERING_CAUSE_DEBT_PAYMENT = 1 << 15, /**< Debt Payment */
|
|
ZB_ZCL_METERING_CAUSE_SCHEDULED_SNAPSHOT = 1 << 16, /**< Scheduled Snapshot */
|
|
ZB_ZCL_METERING_CAUSE_OTA_FIRMWARE_DOWNLOAD = 1 << 17, /**< OTA Firmware Download */
|
|
ZB_ZCL_METERING_CAUSE_SELECT_ALL_SNAPSHOTS = 0xFFFFFFFF /**< Select All Snapshots */
|
|
};
|
|
|
|
|
|
/** Snapshot Payload Type
|
|
* @see SE spec, Table D-53
|
|
*/
|
|
enum zb_zcl_metering_snapshot_payload_type_e
|
|
{
|
|
ZB_ZCL_METERING_TOU_DELIVERED_REGISTERS = 0, /**< TOU Information Set DeliveredRegisters */
|
|
ZB_ZCL_METERING_TOU_RECEIVED_REGISTERS = 1, /**< TOU Information Set Received Registers */
|
|
ZB_ZCL_METERING_BLOCK_TIER_DELIVERED = 2, /**< Block Tier Information Set Delivered */
|
|
ZB_ZCL_METERING_BLOCK_TIER_RECEIVED = 3, /**< Block Tier Information Set Received */
|
|
ZB_ZCL_METERING_TOU_DELIVERED_NO_BILLING = 4, /**< TOU Information Set Delivered (No Billing) */
|
|
ZB_ZCL_METERING_TOU_RECEIVED_NO_BILLING = 5, /**< TOU Information Set Received (No Billing) */
|
|
ZB_ZCL_METERING_BLOCK_TIER_DELIVERED_NO_BILLING = 6, /**< Block Tier Information Set Delivered (No Billing) */
|
|
ZB_ZCL_METERING_BLOCK_TIER_RECEIVED_NO_BILLING = 7, /**< Block Tier Information Set Received (No Billing) */
|
|
ZB_ZCL_METERING_DATA_UNAVAILABLE = 128, /**< Data Unavailable */
|
|
};
|
|
|
|
|
|
/** SnapshotPayloadType 0 = TOU Information Delivered Set
|
|
* @see @ref ZB_ZCL_METERING_TOU_DELIVERED_REGISTERS
|
|
*/
|
|
typedef ZB_PACKED_PRE struct zb_zcl_metering_tou_delivered_payload_s
|
|
{
|
|
/** An unsigned 48-bit integer that returns the value of the CurrentSummationDelivered
|
|
* attribute at the stated snapshot timestamp.
|
|
*/
|
|
zb_uint48_t current_summation_delivered; /* (M) */
|
|
/** An unsigned 32-bit integer that provides a value for the costs in the current billing period. */
|
|
zb_uint32_t bill_to_date_delivered; /* (M) */
|
|
/** A UTC timestamp that indicates when the value of the associated BillToDateDelivered
|
|
* parameter was last updated.
|
|
*/
|
|
zb_uint32_t bill_to_date_time_stamp_delivered; /* (M) */
|
|
/** An unsigned 32-bit integer that provides a value indicating what the estimated state of the
|
|
* account will be at the end of the billing period based on past consumption.
|
|
*/
|
|
zb_uint32_t projected_bill_delivered; /* (M) */
|
|
/** A UTC timestamp that indicates when the associated ProjectedBillDelivered parameter was
|
|
* last updated.
|
|
*/
|
|
zb_uint32_t projected_bill_time_stamp_delivered; /* (M) */
|
|
/** An 8-bit BitMap used to determine where the decimal point is located in the
|
|
* BillToDateDelivered and ProjectedBillDelivered fields.
|
|
*/
|
|
zb_uint8_t bill_delivered_trailing_digit; /* (M) */
|
|
/** An 8-bit integer representing the number of tiers in use at the time the snapshot was taken. */
|
|
zb_uint8_t number_of_tiers_in_use; /* (M) */
|
|
/** The Publish Snapshot command contains N elements of CurrentTierNSummationDelivered attributes
|
|
* from the TOU Information Set. The Metering server shall send only the number of tiers in use,
|
|
* as stated in this command.
|
|
*/
|
|
zb_uint48_t *tier_summation; /* (M) */
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_tou_delivered_payload_t;
|
|
|
|
|
|
/** SnapshotPayloadType 1 = TOU Information Received Set
|
|
* @see @ref ZB_ZCL_METERING_TOU_RECEIVED_REGISTERS
|
|
*/
|
|
typedef ZB_PACKED_PRE struct zb_zcl_metering_tou_received_payload_s
|
|
{
|
|
/** An unsigned 48-bit integer that returns the value of the CurrentSummationReceived
|
|
* attribute at the stated snapshot timestamp.
|
|
*/
|
|
zb_uint48_t current_summation_received; /* (M) */
|
|
/** An unsigned 32-bit integer that provides a value for the costs in the current billing period. */
|
|
zb_uint32_t bill_to_date_received; /* (M) */
|
|
/** A UTC timestamp that indicates when the value of the associated BillToDateReceived parameter
|
|
* was last updated.
|
|
*/
|
|
zb_uint32_t bill_to_date_time_stamp_received; /* (M) */
|
|
/** An unsigned 32-bit integer that provides a value indicating what the estimated state of the
|
|
* account will be at the end of the billing period based on past generation.
|
|
*/
|
|
zb_uint32_t projected_bill_received; /* (M) */
|
|
/** A UTC timestamp that indicates when the associated ProjectedBillReceived parameter was last
|
|
* updated.
|
|
*/
|
|
zb_uint32_t projected_bill_time_stamp_received; /* (M) */
|
|
/** An 8-bit BitMap used to determine where the decimal point is located in the
|
|
* BillToDateReceived and ProjectedBillReceived fields.
|
|
*/
|
|
zb_uint8_t bill_received_trailing_digit; /* (M) */
|
|
/** An 8-bit integer representing the number of tiers in use at the time the snapshot
|
|
* was taken.
|
|
*/
|
|
zb_uint8_t number_of_tiers_in_use; /* (M) */
|
|
/** The Publish Snapshot command contains N elements of CurrentTierNSummationReceived attributes
|
|
* from the TOU Information Set. The Metering server shall send only the number of tiers in use,
|
|
* as stated in this command.
|
|
*/
|
|
zb_uint48_t *tier_summation; /* (M) */
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_tou_received_payload_t;
|
|
|
|
|
|
/** SnapshotPayloadType 2 = Block Information Delivered Set
|
|
* @see @ref ZB_ZCL_METERING_BLOCK_TIER_DELIVERED
|
|
*/
|
|
typedef ZB_PACKED_PRE struct zb_zcl_metering_block_delivered_payload_s
|
|
{
|
|
/** An unsigned 48-bit integer that returns the value of the CurrentSummationDelivered attribute
|
|
* at the stated snapshot timestamp.
|
|
*/
|
|
zb_uint48_t current_summation_delivered; /* (M) */
|
|
/** An unsigned 32-bit integer that provides a value for the costs in the current billing period. */
|
|
zb_uint32_t bill_to_date_delivered; /* (M) */
|
|
/** A UTC timestamp that indicates when the value of the associated BillToDateDelivered
|
|
* parameter was last updated.
|
|
*/
|
|
zb_uint32_t bill_to_date_time_stamp_delivered; /* (M) */
|
|
/** An unsigned 32-bit integer that provides a value indicating what the estimated state of
|
|
* the account will be at the end of the billing period based on past consumption.
|
|
*/
|
|
zb_uint32_t projected_bill_delivered; /* (M) */
|
|
/** A UTC timestamp that indicates when the associated ProjectedBillDelivered parameter was
|
|
* last updated.
|
|
*/
|
|
zb_uint32_t projected_bill_time_stamp_delivered; /* (M) */
|
|
/** An 8-bit BitMap used to determine where the decimal point is located in the
|
|
* BillToDateDelivered and ProjectedBillDelivered fields.
|
|
*/
|
|
zb_uint8_t bill_delivered_trailing_digit; /* (M) */
|
|
/** An 8-bit integer representing the number of tiers in use at the time the snapshot was taken. */
|
|
zb_uint8_t number_of_tiers_in_use; /* (M) */
|
|
/** The Publish Snapshot command contains N elements of CurrentTierNSummationDelivered
|
|
* attributes from the TOU Information Set.
|
|
*/
|
|
zb_uint48_t *tier_summation; /* (M) */
|
|
/** An 8-bit BitMap representing the number of tiers and block thresholds in use at the time the
|
|
* snapshot was taken.
|
|
*/
|
|
zb_uint8_t number_of_tiers_and_block_thresholds_in_use; /* (M) */
|
|
/** The Publish Snapshot command contains N elements of the Block Information Attribute Set
|
|
* (Delivered). The metering server shall send only the number of Tiers and Blocks in use as
|
|
* stated in this command.
|
|
*/
|
|
zb_uint48_t *tier_block_summation; /* (M) */
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_block_delivered_payload_t;
|
|
|
|
|
|
/** SnapshotPayloadType 3 = Block Information Received Set
|
|
* @see @ref ZB_ZCL_METERING_BLOCK_TIER_RECEIVED
|
|
*/
|
|
typedef ZB_PACKED_PRE struct zb_zcl_metering_block_received_payload_s
|
|
{
|
|
/** An unsigned 48-bit integer that returns the value of the CurrentSummationReceived attribute
|
|
* at the stated snapshot timestamp.
|
|
*/
|
|
zb_uint48_t current_summation_received; /* (M) */
|
|
/** An unsigned 32-bit integer that provides a value for the costs in the current billing period. */
|
|
zb_uint32_t bill_to_date_received; /* (M) */
|
|
/** A UTC timestamp that indicates when the value of the associated BillToDateReceived parameter
|
|
* was last updated.
|
|
*/
|
|
zb_uint32_t bill_to_date_time_stamp_received; /* (M) */
|
|
/** An unsigned 32-bit integer that provides a value indicating what the estimated state of the
|
|
* account will be at the end of the billing period based on past generation.
|
|
*/
|
|
zb_uint32_t projected_bill_received; /* (M) */
|
|
/** A UTC timestamp that indicates when the associated ProjectedBillReceived parameter was last
|
|
* updated.
|
|
*/
|
|
zb_uint32_t projected_bill_time_stamp_received; /* (M) */
|
|
/** An 8-bit BitMap used to determine where the decimal point is located in the
|
|
* BillToDateReceived and ProjectedBillReceived fields
|
|
*/
|
|
zb_uint8_t bill_received_trailing_digit; /* (M) */
|
|
/** An 8-bit integer representing the number of tiers in use at the time the snapshot was taken. */
|
|
zb_uint8_t number_of_tiers_in_use; /* (M) */
|
|
/** The Publish Snapshot command contains N elements of CurrentTierNSummationReceived attributes
|
|
* from the TOU Information Set.
|
|
*/
|
|
zb_uint48_t *tier_summation; /* (M) */
|
|
/** An 8-bit BitMap representing the number of tiers and block thresholds in use at the time the
|
|
* snapshot was taken.
|
|
*/
|
|
zb_uint8_t number_of_tiers_and_block_thresholds_in_use; /* (M) */
|
|
/** The Publish Snapshot command contains N elements of the Block Information Attribute Set
|
|
* (Received).
|
|
*/
|
|
zb_uint48_t *tier_block_summation; /* (M) */
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_block_received_payload_t;
|
|
|
|
|
|
/** SnapshotPayloadType 4 = TOU Information Set Delivered (No Billing)
|
|
* @see @ref ZB_ZCL_METERING_TOU_DELIVERED_NO_BILLING
|
|
*/
|
|
typedef ZB_PACKED_PRE struct zb_zcl_metering_tou_delivered_no_billing_payload_s
|
|
{
|
|
/** An unsigned 48-bit integer that returns the value of the CurrentSummationDelivered attribute
|
|
* at the stated snapshot timestamp.
|
|
*/
|
|
zb_uint48_t current_summation_delivered; /* (M) */
|
|
/** An 8-bit integer representing the number of tiers in use at the time the snapshot was taken. */
|
|
zb_uint8_t number_of_tiers_in_use; /* (M) */
|
|
/** The Publish Snapshot command contains N elements of CurrentTierNSummationDelivered attributes
|
|
* from the TOU Information Set.
|
|
*/
|
|
zb_uint48_t *tier_summation; /* (M) */
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_tou_delivered_no_billing_payload_t;
|
|
|
|
|
|
/** SnapshotPayloadType 5 = TOU Information Set Received (No Billing)
|
|
* @see @ref ZB_ZCL_METERING_TOU_RECEIVED_NO_BILLING
|
|
*/
|
|
typedef ZB_PACKED_PRE struct zb_zcl_metering_tou_received_no_billing_payload_s
|
|
{
|
|
/** An unsigned 48-bit integer that returns the value of the CurrentSummationReceived attribute
|
|
* at the stated snapshot timestamp.
|
|
*/
|
|
zb_uint48_t current_summation_received; /* (M) */
|
|
/** An 8-bit integer representing the number of tiers in use at the time the snapshot was taken. */
|
|
zb_uint8_t number_of_tiers_in_use; /* (M) */
|
|
/** The Publish Snapshot command contains N elements of CurrentTierNSummationReceived attributes
|
|
* from the TOU Information Set.
|
|
*/
|
|
zb_uint48_t *tier_summation; /* (M) */
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_tou_received_no_billing_payload_t;
|
|
|
|
|
|
/** SnapshotPayloadType 6 = Block Tier Information Set Delivered (No Billing)
|
|
* @see @ref ZB_ZCL_METERING_BLOCK_TIER_DELIVERED_NO_BILLING
|
|
*/
|
|
typedef ZB_PACKED_PRE struct zb_zcl_metering_block_tier_delivered_no_billing_payload_s
|
|
{
|
|
/** An unsigned 48-bit integer that returns the value of the CurrentSummationDelivered attribute
|
|
* at the stated snapshot timestamp.
|
|
*/
|
|
zb_uint48_t current_summation_delivered; /* (M) */
|
|
/** An 8-bit integer representing the number of tiers in use at the time the snapshot was taken. */
|
|
zb_uint8_t number_of_tiers_in_use; /* (M) */
|
|
/** The Publish Snapshot command contains N elements of CurrentTierNSummationDelivered attributes
|
|
* from the TOU Information Set.
|
|
*/
|
|
zb_uint48_t *tier_summation; /* (M) */
|
|
/** An 8-bit BitMap representing the number of tiers and block thresholds in use at the time the
|
|
* snapshot was taken.
|
|
*/
|
|
zb_uint8_t number_of_tiers_and_block_thresholds_in_use; /* (M) */
|
|
/** The Publish Snapshot command contains N elements of the Block Information Attribute Set
|
|
* (Delivered). The metering server shall send only the number of Tiers and Blocks in use as
|
|
* stated in this command.
|
|
*/
|
|
zb_uint48_t *tier_block_summation; /* (M) */
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_block_tier_delivered_no_billing_payload_t;
|
|
|
|
|
|
/** SnapshotPayloadType 7 = Block Tier Information Set Received (No Billing)
|
|
* @see @ref ZB_ZCL_METERING_BLOCK_TIER_RECEIVED_NO_BILLING
|
|
*/
|
|
typedef ZB_PACKED_PRE struct zb_zcl_metering_block_tier_received_no_billing_payload_s
|
|
{
|
|
/** An unsigned 48-bit integer that returns the value of the CurrentSummationReceived attribute
|
|
* at the stated snapshot timestamp.
|
|
*/
|
|
zb_uint48_t current_summation_received; /* (M) */
|
|
/** An 8-bit integer representing the number of tiers in use at the time the snapshot was taken.*/
|
|
zb_uint8_t number_of_tiers_in_use; /* (M) */
|
|
/** The Publish Snapshot command contains N elements of CurrentTierNSummationReceived attributes
|
|
* from the TOU Information Set.
|
|
*/
|
|
zb_uint48_t *tier_summation; /* (M) */
|
|
/** An 8-bit BitMap representing the number of tiers and block thresholds in use at the time the
|
|
* snapshot was taken.
|
|
*/
|
|
zb_uint8_t number_of_tiers_and_block_thresholds_in_use; /* (M) */
|
|
/** The Publish Snapshot command contains N elements of the Block Information Attribute Set
|
|
* (Received).
|
|
*/
|
|
zb_uint48_t *tier_block_summation; /* (M) */
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_block_tier_received_no_billing_payload_t;
|
|
|
|
|
|
/** The format of the Snapshot Sub-Payload differs depending on the SnapshotPayloadType
|
|
* @see SE spec, Table D-53 and D.3.2.3.1.7
|
|
*/
|
|
typedef ZB_PACKED_PRE union zb_zcl_metering_snapshot_sub_payload_s
|
|
{
|
|
/** @see @ref zb_zcl_metering_tou_delivered_payload_s
|
|
* @see @ref ZB_ZCL_METERING_TOU_DELIVERED_REGISTERS */
|
|
zb_zcl_metering_tou_delivered_payload_t tou_delivered;
|
|
/** @see @ref zb_zcl_metering_tou_received_payload_s
|
|
* @see @ref ZB_ZCL_METERING_TOU_RECEIVED_REGISTERS */
|
|
zb_zcl_metering_tou_received_payload_t tou_received;
|
|
/** @see @ref zb_zcl_metering_block_delivered_payload_s
|
|
* @see @ref ZB_ZCL_METERING_BLOCK_TIER_DELIVERED */
|
|
zb_zcl_metering_block_delivered_payload_t block_delivered;
|
|
/** @see @ref zb_zcl_metering_block_received_payload_s
|
|
* @see @ref ZB_ZCL_METERING_BLOCK_TIER_RECEIVED */
|
|
zb_zcl_metering_block_received_payload_t block_received;
|
|
/** @see @ref zb_zcl_metering_tou_delivered_no_billing_payload_s
|
|
* @see @ref ZB_ZCL_METERING_TOU_DELIVERED_NO_BILLING */
|
|
zb_zcl_metering_tou_delivered_no_billing_payload_t tou_delivered_no_billing;
|
|
/** @see @ref zb_zcl_metering_tou_received_no_billing_payload_s
|
|
* @see @ref ZB_ZCL_METERING_TOU_RECEIVED_NO_BILLING */
|
|
zb_zcl_metering_tou_received_no_billing_payload_t tou_received_no_billing;
|
|
/** @see @ref zb_zcl_metering_block_tier_delivered_no_billing_payload_s
|
|
* @see @ref ZB_ZCL_METERING_BLOCK_TIER_DELIVERED_NO_BILLING */
|
|
zb_zcl_metering_block_tier_delivered_no_billing_payload_t block_tier_delivered_no_billing;
|
|
/** @see @ref zb_zcl_metering_block_tier_received_no_billing_payload_s
|
|
* @see @ref ZB_ZCL_METERING_BLOCK_TIER_RECEIVED_NO_BILLING */
|
|
zb_zcl_metering_block_tier_received_no_billing_payload_t block_tier_received_no_billing;
|
|
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_snapshot_sub_payload_t;
|
|
|
|
|
|
/** @ref ZB_ZCL_METERING_SRV_CMD_PUBLISH_SNAPSHOT "PublishSnapshot" command payload
|
|
* @see SE spec, subclause D.3.2.3.1.7
|
|
*/
|
|
typedef ZB_PACKED_PRE struct zb_zcl_metering_publish_snapshot_payload_s
|
|
{
|
|
/** Unique identifier allocated by the device creating the snapshot. */
|
|
zb_uint32_t snapshot_id; /* (M) */
|
|
/** This is a 32-bit value (in UTC Time) representing the time at which the data snapshot was taken. */
|
|
zb_uint32_t snapshot_time; /* (M) */
|
|
/** An 8-bit Integer indicating the number of snapshots found, based on the search criteria
|
|
* defined in the associated GetSnapshot command.
|
|
*/
|
|
zb_uint8_t total_snapshots_found; /* (M) */
|
|
/** The CommandIndex is used to count the payload fragments in the case where the entire payload
|
|
* (snapshot) does not fit into one message
|
|
*/
|
|
zb_uint8_t command_index; /* (M) */
|
|
/** In the case where the entire payload (snapshot) does not fit into one message, the
|
|
* Total Number of Commands field indicates the total number of sub-commands that will be returned.
|
|
*/
|
|
zb_uint8_t total_number_of_commands; /* (M) */
|
|
/** A 32-bit BitMap indicating the cause of the snapshot */
|
|
zb_uint32_t snapshot_cause; /* (M) */
|
|
/** The SnapshotPayloadType is an 8-bit enumerator defining the format of the Snapshot Sub-Payload
|
|
* in this message.
|
|
*/
|
|
zb_uint8_t snapshot_payload_type; /* (M) */
|
|
|
|
/** @see @ref zb_zcl_metering_snapshot_sub_payload_s */
|
|
zb_zcl_metering_snapshot_sub_payload_t snapshot_sub_payload;
|
|
} ZB_PACKED_STRUCT zb_zcl_metering_publish_snapshot_payload_t;
|
|
|
|
|
|
/** Function for send @ref ZB_ZCL_METERING_CLI_CMD_GET_SNAPSHOT "GetSnapshot" command.
|
|
* On receiver's side callback ZCL device callback @ref ZB_ZCL_REGISTER_DEVICE_CB will be called with
|
|
* @ref ZB_ZCL_METERING_GET_SNAPSHOT_CB_ID
|
|
* @param param - Reference to buffer.
|
|
* @param dst_addr - Address of the device to send command to.
|
|
* @param dst_addr_mode - Address mode for dst_addr.
|
|
* @param dst_ep - Destination endpoint.
|
|
* @param src_ep - Current endpoint.
|
|
* @param payload - Packet payload (ref to @ref zb_zcl_metering_get_snapshot_payload_t).
|
|
* @param cb - Callback which should be called when the ZCL stack receives APS ack.
|
|
*/
|
|
void zb_zcl_metering_send_cmd_get_snapshot(zb_uint8_t param, zb_addr_u *dst_addr,
|
|
zb_aps_addr_mode_t dst_addr_mode, zb_uint8_t dst_ep,
|
|
zb_uint8_t src_ep,
|
|
zb_zcl_metering_get_snapshot_payload_t *payload,
|
|
zb_callback_t cb);
|
|
|
|
|
|
/** Function for send @ref ZB_ZCL_METERING_CLI_CMD_GET_SAMPLED_DATA "GetSampledData" command.
|
|
* On receiver's side callback ZCL device callback @ref ZB_ZCL_REGISTER_DEVICE_CB will be called with
|
|
* @ref ZB_ZCL_METERING_GET_SAMPLED_DATA_CB_ID
|
|
* @param param - Reference to buffer.
|
|
* @param dst_addr - Address of the device to send command to.
|
|
* @param dst_addr_mode - Address mode for dst_addr.
|
|
* @param dst_ep - Destination endpoint.
|
|
* @param src_ep - Current endpoint.
|
|
* @param payload - Packet payload (ref to @ref zb_zcl_metering_get_sampled_data_payload_t).
|
|
* @param cb - Callback which should be called when the ZCL stack receives APS ack.
|
|
*/
|
|
void zb_zcl_metering_send_cmd_get_sampled_data(zb_uint8_t param, zb_addr_u *dst_addr,
|
|
zb_aps_addr_mode_t dst_addr_mode, zb_uint8_t dst_ep,
|
|
zb_uint8_t src_ep,
|
|
zb_zcl_metering_get_sampled_data_payload_t *payload,
|
|
zb_callback_t cb);
|
|
|
|
|
|
/** Function for send @ref ZB_ZCL_METERING_CLI_CMD_REQUEST_FAST_POLL_MODE "RequestFastPollMode" command.
|
|
* On receiver's side callback ZCL device callback @ref ZB_ZCL_REGISTER_DEVICE_CB will be called with
|
|
* @ref ZB_ZCL_METERING_REQUEST_FAST_POLL_MODE_CB_ID
|
|
* @param param - Reference to buffer.
|
|
* @param dst_addr - Address of the device to send command to.
|
|
* @param dst_addr_mode - Address mode for dst_addr.
|
|
* @param dst_ep - Destination endpoint.
|
|
* @param src_ep - Current endpoint.
|
|
* @param payload - Packet payload (ref to @ref zb_zcl_metering_request_fast_poll_mode_payload_t).
|
|
* @param cb - Callback which should be called when the ZCL stack receives APS ack.
|
|
*/
|
|
void zb_zcl_metering_send_cmd_request_fast_poll_mode(zb_uint8_t param, zb_addr_u *dst_addr,
|
|
zb_aps_addr_mode_t dst_addr_mode, zb_uint8_t dst_ep,
|
|
zb_uint8_t src_ep,
|
|
zb_zcl_metering_request_fast_poll_mode_payload_t *payload,
|
|
zb_callback_t cb);
|
|
|
|
|
|
/** Function for send @ref ZB_ZCL_METERING_CLI_CMD_GET_PROFILE "GetProfile" command.
|
|
* On receiver's side callback ZCL device callback @ref ZB_ZCL_REGISTER_DEVICE_CB will be called with
|
|
* @ref ZB_ZCL_METERING_GET_PROFILE_CB_ID
|
|
* @param param - Reference to buffer.
|
|
* @param dst_addr - Address of the device to send command to.
|
|
* @param dst_addr_mode - Address mode for dst_addr.
|
|
* @param dst_ep - Destination endpoint.
|
|
* @param src_ep - Current endpoint.
|
|
* @param payload - Packet payload (ref to @ref zb_zcl_metering_get_profile_payload_t).
|
|
* @param cb - Callback which should be called when the ZCL stack receives APS ack.
|
|
*/
|
|
void zb_zcl_metering_send_cmd_get_profile(zb_uint8_t param, zb_addr_u *dst_addr,
|
|
zb_aps_addr_mode_t dst_addr_mode, zb_uint8_t dst_ep,
|
|
zb_uint8_t src_ep, zb_zcl_metering_get_profile_payload_t *payload,
|
|
zb_callback_t cb);
|
|
|
|
|
|
/** Function for send @ref ZB_ZCL_METERING_SRV_CMD_PUBLISH_SNAPSHOT "PublishSnapshot" command.
|
|
* On receiver's side callback ZCL device callback @ref ZB_ZCL_REGISTER_DEVICE_CB will be called with
|
|
* @ref ZB_ZCL_METERING_PUBLISH_SNAPSHOT_CB_ID
|
|
* @param param - Reference to buffer.
|
|
* @param dst_addr - Address of the device to send command to.
|
|
* @param dst_addr_mode - Address mode for dst_addr.
|
|
* @param dst_ep - Destination endpoint.
|
|
* @param src_ep - Current endpoint.
|
|
* @param pl - Packet payload (ref to @ref zb_zcl_metering_publish_snapshot_payload_t).
|
|
* @param cb - Callback which should be called when the ZCL stack receives APS ack.
|
|
*/
|
|
void zb_zcl_metering_send_cmd_publish_snapshot(zb_uint8_t param, const zb_addr_u *dst_addr,
|
|
zb_aps_addr_mode_t dst_addr_mode, zb_uint8_t dst_ep,
|
|
zb_uint8_t src_ep,
|
|
const zb_zcl_metering_publish_snapshot_payload_t *pl,
|
|
zb_callback_t cb);
|
|
|
|
|
|
/** Function for send @ref ZB_ZCL_METERING_SRV_CMD_REQUEST_FAST_POLL_MODE_RESPONSE "RequestFastPollMode" command.
|
|
* On receiver's side callback ZCL device callback @ref ZB_ZCL_REGISTER_DEVICE_CB will be called with
|
|
* @ref ZB_ZCL_METERING_REQUEST_FAST_POLL_MODE_CB_ID
|
|
* @param param - Reference to buffer.
|
|
* @param dst_addr - Address of the device to send command to.
|
|
* @param dst_addr_mode - Address mode for dst_addr.
|
|
* @param dst_ep - Destination endpoint.
|
|
* @param src_ep - Current endpoint.
|
|
* @param pl - Packet payload (ref to @ref zb_zcl_metering_request_fast_poll_mode_response_payload_t).
|
|
* @param pl_size - size in bytes of input payload. Stack can calculate actual payload size.
|
|
* Set pl_size to 0 for it.
|
|
* @param tsn - transaction sequence number of response
|
|
* @param cb - Callback which should be called when the ZCL stack receives APS ack.
|
|
*/
|
|
void zb_zcl_metering_send_cmd_request_fast_poll_mode_response(zb_uint8_t param, const zb_addr_u *dst_addr,
|
|
zb_aps_addr_mode_t dst_addr_mode, zb_uint8_t dst_ep,
|
|
zb_uint8_t src_ep,
|
|
const zb_zcl_metering_request_fast_poll_mode_response_payload_t *pl,
|
|
zb_uint8_t pl_size, zb_uint8_t tsn, zb_callback_t cb);
|
|
|
|
|
|
/** Function for send @ref ZB_ZCL_METERING_SRV_CMD_GET_PROFILE_RESPONSE "GetProfileResponse" command.
|
|
* On receiver's side callback ZCL device callback @ref ZB_ZCL_REGISTER_DEVICE_CB will be called with
|
|
* @ref ZB_ZCL_METERING_GET_PROFILE_RESPONSE_CB_ID
|
|
* @param param - Reference to buffer.
|
|
* @param dst_addr - Address of the device to send command to.
|
|
* @param dst_addr_mode - Address mode for dst_addr.
|
|
* @param dst_ep - Destination endpoint.
|
|
* @param src_ep - Current endpoint.
|
|
* @param pl - Packet payload (ref to @ref zb_zcl_metering_get_profile_response_payload_t).
|
|
* @param pl_size - size in bytes of input payload. Stack can calculate actual payload size.
|
|
* Set pl_size to 0 for it.
|
|
* @param tsn - transaction sequence number of response
|
|
* @param cb - Callback which should be called when the ZCL stack receives APS ack.
|
|
*/
|
|
void zb_zcl_metering_send_cmd_get_profile_response(zb_uint8_t param, const zb_addr_u *dst_addr,
|
|
zb_aps_addr_mode_t dst_addr_mode, zb_uint8_t dst_ep,
|
|
zb_uint8_t src_ep, const zb_zcl_metering_get_profile_response_payload_t *pl,
|
|
zb_uint8_t pl_size, zb_uint8_t tsn, zb_callback_t cb);
|
|
|
|
|
|
/** Function for send @ref ZB_ZCL_METERING_SRV_CMD_GET_PROFILE_RESPONSE "GetSampledDataResponse" command.
|
|
* On receiver's side callback ZCL device callback @ref ZB_ZCL_REGISTER_DEVICE_CB will be called with
|
|
* @ref ZB_ZCL_METERING_GET_SAMPLED_DATA_RESPONSE_CB_ID
|
|
* @param param - Reference to buffer.
|
|
* @param dst_addr - Address of the device to send command to.
|
|
* @param dst_addr_mode - Address mode for dst_addr.
|
|
* @param dst_ep - Destination endpoint.
|
|
* @param src_ep - Current endpoint.
|
|
* @param pl - Packet payload (ref to @ref zb_zcl_metering_get_sampled_data_response_payload_t).
|
|
* @param pl_size - size in bytes of input payload. Stack can calculate actual payload size.
|
|
* Set pl_size to 0 for it.
|
|
* @param tsn - transaction sequence number of response
|
|
* @param cb - Callback which should be called when the ZCL stack receives APS ack.
|
|
*/
|
|
void zb_zcl_metering_send_cmd_get_sampled_data_response(zb_uint8_t param, const zb_addr_u *dst_addr,
|
|
zb_aps_addr_mode_t dst_addr_mode, zb_uint8_t dst_ep,
|
|
zb_uint8_t src_ep,
|
|
const zb_zcl_metering_get_sampled_data_response_payload_t *pl,
|
|
zb_uint8_t pl_size, zb_uint8_t tsn, zb_callback_t cb);
|
|
|
|
/** Macro for call @ref zb_zcl_metering_send_cmd_get_snapshot function
|
|
*/
|
|
#define ZB_ZCL_METERING_SEND_CMD_GET_SNAPSHOT(_param, _dst_addr, _addr_mode, \
|
|
_dst_ep, _src_ep, _payload, cb) \
|
|
zb_zcl_metering_send_cmd_get_snapshot(_param, _dst_addr, _addr_mode, \
|
|
_dst_ep, _src_ep, _payload, cb)
|
|
|
|
|
|
/** Macro for call @ref zb_zcl_metering_send_cmd_get_sampled_data function
|
|
*/
|
|
#define ZB_ZCL_METERING_SEND_CMD_GET_SAMPLED_DATA(_param, _dst_addr, _addr_mode, \
|
|
_dst_ep, _src_ep, _payload, cb) \
|
|
zb_zcl_metering_send_cmd_get_sampled_data(_param, _dst_addr, _addr_mode, \
|
|
_dst_ep, _src_ep, _payload, cb)
|
|
|
|
|
|
|
|
/** Macro for call @ref zb_zcl_metering_send_cmd_request_fast_poll_mode function
|
|
*/
|
|
#define ZB_ZCL_METERING_SEND_CMD_REQUEST_FAST_POLL_MODE(_param, _dst_addr, _addr_mode, \
|
|
_dst_ep, _src_ep, _payload, cb) \
|
|
zb_zcl_metering_send_cmd_request_fast_poll_mode(_param, _dst_addr, _addr_mode, \
|
|
_dst_ep, _src_ep, _payload, cb)
|
|
|
|
|
|
/** Macro for call @ref zb_zcl_metering_send_cmd_get_profile function
|
|
*/
|
|
#define ZB_ZCL_METERING_SEND_CMD_GET_PROFILE(_param, _dst_addr, _addr_mode, \
|
|
_dst_ep, _src_ep, _payload, cb) \
|
|
zb_zcl_metering_send_cmd_get_profile(_param, _dst_addr, _addr_mode, \
|
|
_dst_ep, _src_ep, _payload, cb)
|
|
|
|
|
|
/** Macro for call @ref zb_zcl_metering_send_cmd_publish_snapshot function
|
|
*/
|
|
#define ZB_ZCL_METERING_SEND_CMD_PUBLISH_SNAPSHOT(_param, _dst_addr, _addr_mode, \
|
|
_dst_ep, _src_ep, _payload, cb) \
|
|
zb_zcl_metering_send_cmd_publish_snapshot(_param, _dst_addr, _addr_mode, \
|
|
_dst_ep, _src_ep, _payload, cb)
|
|
|
|
|
|
/** Macro for call @ref zb_zcl_metering_send_cmd_request_fast_poll_mode_response function
|
|
*/
|
|
#define ZB_ZCL_METERING_SEND_CMD_REQUEST_FAST_POLL_MODE_RESPONSE(_param, _dst_addr, _addr_mode, \
|
|
_dst_ep, _src_ep, _payload, cb) \
|
|
zb_zcl_metering_send_cmd_request_fast_poll_mode_response(_param, _dst_addr, _addr_mode, \
|
|
_dst_ep, _src_ep, _payload, cb)
|
|
|
|
|
|
/** Macro for call @ref zb_zcl_metering_send_cmd_get_profile_response function
|
|
*/
|
|
#define ZB_ZCL_METERING_SEND_CMD_GET_PROFILE_RESPONSE(_param, _dst_addr, _addr_mode, _dst_ep, \
|
|
_src_ep, _payload, _pl_size, cb) \
|
|
zb_zcl_metering_send_cmd_get_profile_response(_param, _dst_addr, _addr_mode, _dst_ep, \
|
|
_src_ep, _payload, _pl_size, cb)
|
|
|
|
|
|
/** Macro for call @ref zb_zcl_metering_send_cmd_get_sampled_data_response function
|
|
*/
|
|
#define ZB_ZCL_METERING_SEND_CMD_GET_SAMPLED_DATA_RESPONSE(_param, _dst_addr, _addr_mode, _dst_ep, \
|
|
_src_ep, _payload, _pl_size, cb) \
|
|
zb_zcl_metering_send_cmd_get_sampled_data_response(_param, _dst_addr, _addr_mode, _dst_ep, \
|
|
_src_ep, _payload, _pl_size, cb)
|
|
|
|
|
|
/** @} */ /* ZB_ZCL_METERING_CMDS */
|
|
|
|
|
|
/*! @cond internals_doc */
|
|
/*! @internal @name Metering cluster internals
|
|
Internal structures for attribute representation in cluster definitions.
|
|
@{
|
|
*/
|
|
|
|
#define ZB_SET_ATTR_DESCR_WITH_ZB_ZCL_ATTR_METERING_CURRENT_SUMMATION_DELIVERED_ID(data_ptr) \
|
|
{ \
|
|
ZB_ZCL_ATTR_METERING_CURRENT_SUMMATION_DELIVERED_ID, \
|
|
ZB_ZCL_ATTR_TYPE_U48, \
|
|
ZB_ZCL_ATTR_ACCESS_READ_ONLY | ZB_ZCL_ATTR_ACCESS_REPORTING, \
|
|
(ZB_ZCL_NON_MANUFACTURER_SPECIFIC), \
|
|
(void*) data_ptr \
|
|
}
|
|
|
|
#define ZB_SET_ATTR_DESCR_WITH_ZB_ZCL_ATTR_METERING_STATUS_ID(data_ptr) \
|
|
{ \
|
|
ZB_ZCL_ATTR_METERING_STATUS_ID, \
|
|
ZB_ZCL_ATTR_TYPE_8BITMAP, \
|
|
ZB_ZCL_ATTR_ACCESS_READ_ONLY | ZB_ZCL_ATTR_ACCESS_REPORTING, \
|
|
(ZB_ZCL_NON_MANUFACTURER_SPECIFIC), \
|
|
(void*) data_ptr \
|
|
}
|
|
|
|
#define ZB_SET_ATTR_DESCR_WITH_ZB_ZCL_ATTR_METERING_UNIT_OF_MEASURE_ID(data_ptr) \
|
|
{ \
|
|
ZB_ZCL_ATTR_METERING_UNIT_OF_MEASURE_ID, \
|
|
ZB_ZCL_ATTR_TYPE_8BIT_ENUM, \
|
|
ZB_ZCL_ATTR_ACCESS_READ_ONLY, \
|
|
(ZB_ZCL_NON_MANUFACTURER_SPECIFIC), \
|
|
(void*) data_ptr \
|
|
}
|
|
|
|
#define ZB_SET_ATTR_DESCR_WITH_ZB_ZCL_ATTR_METERING_SUMMATION_FORMATTING_ID(data_ptr) \
|
|
{ \
|
|
ZB_ZCL_ATTR_METERING_SUMMATION_FORMATTING_ID, \
|
|
ZB_ZCL_ATTR_TYPE_8BITMAP, \
|
|
ZB_ZCL_ATTR_ACCESS_READ_ONLY, \
|
|
(ZB_ZCL_NON_MANUFACTURER_SPECIFIC), \
|
|
(void*) data_ptr \
|
|
}
|
|
|
|
#define ZB_SET_ATTR_DESCR_WITH_ZB_ZCL_ATTR_METERING_METERING_DEVICE_TYPE_ID(data_ptr) \
|
|
{ \
|
|
ZB_ZCL_ATTR_METERING_METERING_DEVICE_TYPE_ID, \
|
|
ZB_ZCL_ATTR_TYPE_8BITMAP, \
|
|
ZB_ZCL_ATTR_ACCESS_READ_ONLY, \
|
|
(ZB_ZCL_NON_MANUFACTURER_SPECIFIC), \
|
|
(void*) data_ptr \
|
|
}
|
|
|
|
#define ZB_SET_ATTR_DESCR_WITH_ZB_ZCL_ATTR_METERING_INSTANTANEOUS_DEMAND_ID(data_ptr) \
|
|
{ \
|
|
ZB_ZCL_ATTR_METERING_INSTANTANEOUS_DEMAND_ID, \
|
|
ZB_ZCL_ATTR_TYPE_S24, \
|
|
ZB_ZCL_ATTR_ACCESS_READ_ONLY | ZB_ZCL_ATTR_ACCESS_REPORTING, \
|
|
(ZB_ZCL_NON_MANUFACTURER_SPECIFIC), \
|
|
(void*) data_ptr \
|
|
}
|
|
|
|
#define ZB_SET_ATTR_DESCR_WITH_ZB_ZCL_ATTR_METERING_DEMAND_FORMATTING_ID(data_ptr) \
|
|
{ \
|
|
ZB_ZCL_ATTR_METERING_DEMAND_FORMATTING_ID, \
|
|
ZB_ZCL_ATTR_TYPE_8BITMAP, \
|
|
ZB_ZCL_ATTR_ACCESS_READ_ONLY, \
|
|
(ZB_ZCL_NON_MANUFACTURER_SPECIFIC), \
|
|
(void*) data_ptr \
|
|
}
|
|
|
|
#define ZB_SET_ATTR_DESCR_WITH_ZB_ZCL_ATTR_METERING_HISTORICAL_CONSUMPTION_FORMATTING_ID(data_ptr) \
|
|
{ \
|
|
ZB_ZCL_ATTR_METERING_HISTORICAL_CONSUMPTION_FORMATTING_ID, \
|
|
ZB_ZCL_ATTR_TYPE_8BITMAP, \
|
|
ZB_ZCL_ATTR_ACCESS_READ_ONLY, \
|
|
(ZB_ZCL_NON_MANUFACTURER_SPECIFIC), \
|
|
(void*) data_ptr \
|
|
}
|
|
|
|
#define ZB_SET_ATTR_DESCR_WITH_ZB_ZCL_ATTR_METERING_MULTIPLIER_ID(data_ptr) \
|
|
{ \
|
|
ZB_ZCL_ATTR_METERING_MULTIPLIER_ID, \
|
|
ZB_ZCL_ATTR_TYPE_U24, \
|
|
ZB_ZCL_ATTR_ACCESS_READ_ONLY, \
|
|
(ZB_ZCL_NON_MANUFACTURER_SPECIFIC), \
|
|
(void*) data_ptr \
|
|
}
|
|
|
|
#define ZB_SET_ATTR_DESCR_WITH_ZB_ZCL_ATTR_METERING_DIVISOR_ID(data_ptr) \
|
|
{ \
|
|
ZB_ZCL_ATTR_METERING_DIVISOR_ID, \
|
|
ZB_ZCL_ATTR_TYPE_U24, \
|
|
ZB_ZCL_ATTR_ACCESS_READ_ONLY, \
|
|
(ZB_ZCL_NON_MANUFACTURER_SPECIFIC), \
|
|
(void*) data_ptr \
|
|
}
|
|
|
|
|
|
/*! @internal Number of attributes mandatory for reporting in Metering cluster */
|
|
#define ZB_ZCL_METERING_REPORT_ATTR_COUNT 3
|
|
|
|
/*! @}
|
|
@endcond */ /* Metering cluster internals */
|
|
|
|
|
|
/** @struct zb_zcl_metering_attrs_t
|
|
* @brief Metering cluster attributes
|
|
*/
|
|
/** @brief Declare attribute list for Electrical Measurement cluster
|
|
@param attr_list - attribute list name
|
|
@param curr_summ_delivered - pointer to variable to store Current Summation Delivered attribute value
|
|
@param status - pointer to variable to store Status attribute value
|
|
@param unit_of_measure - pointer to variable to store Unit Of Measure attribute value
|
|
@param summation_formatting - pointer to variable to store Summation Formatting attribute value
|
|
@param metering_device_type - pointer to variable to store Device Type attribute value
|
|
*/
|
|
#define ZB_ZCL_DECLARE_METERING_ATTRIB_LIST(attr_list, curr_summ_delivered, status, unit_of_measure, \
|
|
summation_formatting, metering_device_type) \
|
|
ZB_ZCL_START_DECLARE_ATTRIB_LIST_CLUSTER_REVISION(attr_list, ZB_ZCL_METERING) \
|
|
ZB_ZCL_SET_ATTR_DESC(ZB_ZCL_ATTR_METERING_CURRENT_SUMMATION_DELIVERED_ID, (curr_summ_delivered)) \
|
|
ZB_ZCL_SET_ATTR_DESC(ZB_ZCL_ATTR_METERING_STATUS_ID, (status)) \
|
|
ZB_ZCL_SET_ATTR_DESC(ZB_ZCL_ATTR_METERING_UNIT_OF_MEASURE_ID, (unit_of_measure)) \
|
|
ZB_ZCL_SET_ATTR_DESC(ZB_ZCL_ATTR_METERING_SUMMATION_FORMATTING_ID, (summation_formatting)) \
|
|
ZB_ZCL_SET_ATTR_DESC(ZB_ZCL_ATTR_METERING_METERING_DEVICE_TYPE_ID, (metering_device_type)) \
|
|
ZB_ZCL_FINISH_DECLARE_ATTRIB_LIST
|
|
|
|
|
|
/** @brief Declare attribute list for Electrical Measurement cluster (extended attribute set)
|
|
@param attr_list - attribute list name
|
|
@param curr_summ_delivered - pointer to variable to store Current Summ Delivered attribute value
|
|
@param status - pointer to variable to store Status attribute value
|
|
@param unit_of_measure - pointer to variable to store Unit Of Measure attribute value
|
|
@param summation_formatting - pointer to variable to store Summation Formatting attribute value
|
|
@param metering_device_type - pointer to variable to store Device Type attribute value
|
|
@param instantaneous_demand - pointer to variable to store Instantaneous Demand attribute value
|
|
@param demand_formatting - pointer to variable to store Demand Formatting attribute value
|
|
@param historical_consumption_formatting - pointer to variable to store Historical Consumption Formatting attribute value
|
|
@param multiplier - pointer to variable to store Multiplier attribute value
|
|
@param divisor - pointer to variable to store Divisor attribute value
|
|
*/
|
|
#define ZB_ZCL_DECLARE_METERING_ATTRIB_LIST_EXT(attr_list, \
|
|
curr_summ_delivered, status, unit_of_measure, summation_formatting, metering_device_type, \
|
|
instantaneous_demand, demand_formatting, historical_consumption_formatting, multiplier, divisor) \
|
|
ZB_ZCL_START_DECLARE_ATTRIB_LIST_CLUSTER_REVISION(attr_list, ZB_ZCL_METERING) \
|
|
ZB_ZCL_SET_ATTR_DESC(ZB_ZCL_ATTR_METERING_CURRENT_SUMMATION_DELIVERED_ID, (curr_summ_delivered)) \
|
|
ZB_ZCL_SET_ATTR_DESC(ZB_ZCL_ATTR_METERING_STATUS_ID, (status)) \
|
|
ZB_ZCL_SET_ATTR_DESC(ZB_ZCL_ATTR_METERING_UNIT_OF_MEASURE_ID, (unit_of_measure)) \
|
|
ZB_ZCL_SET_ATTR_DESC(ZB_ZCL_ATTR_METERING_SUMMATION_FORMATTING_ID, (summation_formatting)) \
|
|
ZB_ZCL_SET_ATTR_DESC(ZB_ZCL_ATTR_METERING_METERING_DEVICE_TYPE_ID, (metering_device_type)) \
|
|
ZB_ZCL_SET_ATTR_DESC(ZB_ZCL_ATTR_METERING_INSTANTANEOUS_DEMAND_ID, (instantaneous_demand)) \
|
|
ZB_ZCL_SET_ATTR_DESC(ZB_ZCL_ATTR_METERING_DEMAND_FORMATTING_ID, (demand_formatting)) \
|
|
ZB_ZCL_SET_ATTR_DESC(ZB_ZCL_ATTR_METERING_HISTORICAL_CONSUMPTION_FORMATTING_ID, (historical_consumption_formatting)) \
|
|
ZB_ZCL_SET_ATTR_DESC(ZB_ZCL_ATTR_METERING_MULTIPLIER_ID, (multiplier)) \
|
|
ZB_ZCL_SET_ATTR_DESC(ZB_ZCL_ATTR_METERING_DIVISOR_ID, (divisor)) \
|
|
ZB_ZCL_FINISH_DECLARE_ATTRIB_LIST
|
|
|
|
typedef struct zb_zcl_metering_attrs_s
|
|
{
|
|
|
|
/** @copydoc ZB_ZCL_ATTR_METERING_CURRENT_SUMMATION_DELIVERED_ID
|
|
* @see ZB_ZCL_ATTR_METERING_CURRENT_SUMMATION_DELIVERED_ID
|
|
*/
|
|
zb_uint48_t curr_summ_delivered;
|
|
|
|
/** @copydoc ZB_ZCL_ATTR_METERING_STATUS_ID
|
|
* @see ZB_ZCL_ATTR_METERING_STATUS_ID
|
|
*/
|
|
zb_uint8_t status;
|
|
|
|
/** @copydoc ZB_ZCL_ATTR_METERING_UNIT_OF_MEASURE_ID
|
|
* @see ZB_ZCL_ATTR_METERING_UNIT_OF_MEASURE_ID
|
|
*/
|
|
zb_uint8_t unit_of_measure;
|
|
|
|
/** @copydoc ZB_ZCL_ATTR_METERING_SUMMATION_FORMATTING_ID
|
|
* @see ZB_ZCL_ATTR_METERING_SUMMATION_FORMATTING_ID
|
|
*/
|
|
zb_uint8_t summation_formatting;
|
|
|
|
/** @copydoc ZB_ZCL_ATTR_METERING_METERING_DEVICE_TYPE_ID
|
|
* @see ZB_ZCL_ATTR_METERING_METERING_DEVICE_TYPE_ID
|
|
*/
|
|
zb_uint8_t device_type;
|
|
} zb_zcl_metering_attrs_t;
|
|
|
|
|
|
/** @brief Declare attribute list for Metering cluster cluster
|
|
* @param[in] attr_list - attribute list variable name
|
|
* @param[in] attrs - variable of @ref zb_zcl_metering_attrs_t type (containing Metering cluster attributes)
|
|
*/
|
|
#define ZB_ZCL_DECLARE_METERING_ATTR_LIST(attr_list, attrs) \
|
|
ZB_ZCL_DECLARE_METERING_ATTRIB_LIST(attr_list, &attrs.curr_summ_delivered, \
|
|
&attrs.status, &attrs.unit_of_measure, &attrs.summation_formatting, \
|
|
&attrs.device_type)
|
|
|
|
|
|
/** @} */ /* ZB_ZCL_METERING ZCL SE Metering cluster definitions */
|
|
|
|
/** @endcond */ /* DOXYGEN_ZCL_SECTION */
|
|
|
|
void zb_zcl_metering_init_server(void);
|
|
void zb_zcl_metering_init_client(void);
|
|
|
|
|
|
#define ZB_ZCL_CLUSTER_ID_METERING_SERVER_ROLE_INIT zb_zcl_metering_init_server
|
|
#define ZB_ZCL_CLUSTER_ID_METERING_CLIENT_ROLE_INIT zb_zcl_metering_init_client
|
|
|
|
#endif /* ZB_ZCL_METERING_H */
|